TP-CU3-ZD and TP-CU3 Content

 
This guide provides the initial steps to set up and configure the following Tap models:

•  TP-CU3-ZD 

10/100/1000 Tap with Zero Delay

•  TP-CU3-ZD-DC 10/100/1000 Tap with Zero Delay, -48V DC power
•  TP-CU3 

10/100/1000 Tap

•  TP-CU3-DC 

10/100/1000 Tap, -48V DC power

 
Carefully unpack the Tap and check for damaged or missing parts. 

•  2 Power cords and power supplies, 12VDC, 3.3A, 2.5mm, IEC-C13

•  2 Power cords and power supplies, 12VDC, 1.5A, 2.5mm, IEC-C13 (TP-

CU3 only)

•  Retainer clip (not included with -DC models)

•  3 CAT 5e 4-pair (purple) cable, 3-meter, RJ45

•  1 CAT 5e 4-pair (green) Crossover cable, 3-meter, RJ45

•  Registration card

You may have also ordered a panel for rack mounting and an extended warranty. Check 
the packing slip against parts received. If any component is missing or damaged, 
contact our Order Management department via email at Order-Management@

ixiacom.com or if this is a Demo unit, contact [email protected].

Содержание TP-CU3

Страница 1: ...TP CU3 ZD DC Gig Zero Delay Quick Install Guide 913 2114 01 Rev B 1 15 TP CU3 DC 10 100 1000BaseT Tap...

Страница 2: ...DFARS 252 227 7013 and FAR 52 227 19 Ixia the Ixia logo and all Ixia brand names and product names in this document are either trademarks or registered trademarks of Ixia in the United States and or o...

Страница 3: ...ntent 4 TP CU3 ZD and TP CU3 Overview 5 Step 1 Rack Mount Tap 7 Step 2 Connect AC Power 9 Connect DC Power 10 Step 3 Configure the DIP Switches 11 Step 4 Connect to the Network 14 Step 5 Connect to th...

Страница 4: ...d power supplies 12VDC 3 3A 2 5mm IEC C13 2 Power cords and power supplies 12VDC 1 5A 2 5mm IEC C13 TP CU3 only Retainer clip not included with DC models 3 CAT 5e 4 pair purple cable 3 meter RJ45 1 CA...

Страница 5: ...rrent power source LED illuminates white Link Activity Indicator Located in the upper right corner If a good link is established the LED lights up The LED flashes when there is activity 10 100 1000 In...

Страница 6: ...Rear Panel DC power model TP CU3 DC Figure 5 Rear Panel DC power model TP CU3 ZD DC Power DC Jacks Retainer Clip DIP Switch 1 3 4 5 6 7 8 2 For use with 48 only Terminal Blocks DIP Switch 1 3 4 5 6 7...

Страница 7: ...ollowing 1 Remove the panel and screws from the shipping bag 2 Screw the panel onto the rack 3 Slide the switches in place in the rack See Figure 6 See Figure 7 if you ordered the 12 Slot version 4 Fa...

Страница 8: ...8 Figure 7 Tall 12 Slot Version...

Страница 9: ...d to a power source See Figure 8 2 For redundancy plug the other power cord to the other connector Plug the other end to a source independent from the first power source The second power supply is ava...

Страница 10: ...or convenience when connecting the power wires Just pull to unplug the removable part and push it back in to reconnect it To connect the power wires insert a wire into a socket and tighten the screw t...

Страница 11: ...ap except for Switch 1 Link Fault Detect which applies only to the Network Ports If you use fixed settings connected devices must match the settings you select for the Tap If you use Auto negotiation...

Страница 12: ...Half duplex If switch 2 is ON this switch is ignored 7 Reserved 8 ON OFF Up position The backup battery is not connected Down position The backup battery is connected The unit is shipped with this swi...

Страница 13: ...wn position After you connect power make sure the power is ON for 12 hours to fully charge the backup battery In the event of a power outage the Zero Delay Tap can remain powered for 3 to 5 hours with...

Страница 14: ...rk Port B to the appropriate switch server or router using one of the supplied purple CAT5e cables 3 Verify that the Tap Network Ports are cabled in line between two devices 4 Verify the link LEDs ill...

Страница 15: ...ing device using one of the supplied purple CAT5e cables 2 Connect Monitor Port B to the appropriate port on the monitoring device using one of the supplied purple CAT5e cables Figure 12 Connecting to...

Страница 16: ...E mail support emea ixiacom com India 91 80 49396410 E mail support india ixiacom com Japan 81 3 5326 1980 E mail support japan ixiacom com APAC 65 6332 0126 E mail support asiapac ixiacom com China 4...