HU
EN
M
HOLD indicator: each time the welding finishes, this indicator will be on and the display will
display the average current and voltage in the welding process.
N
Indicate the current of wire feeder’s motor, so as to judge the smoothness of wire feeding
channel.
O
The right knob is used to move the H, I, J, K, and N to the front panel in order and adjust the
corresponding parameters of H, I, J, K, and N indicators.
P
Gas inspection key. Press this key to enable the gas pass for 30 s and press this key again to
interrupt
Q
Wire inspection key. Press this key to feed wire quickly and release the key to stop feeding.
R
Storage/Call key. When S2 is chose to JOB, it will display a serial number (0-9) on the right
display window, which can be changed by the right knob. Quickly press the Storage/Call
key to call the welding parameters of relevant serial number. Press the Storage/Call key
and hold for 3 s to store the welding parameters in relevant serial number.
S
Function key of PMIG. When the welding mode is PMIG, this indicator will be on.
T
Function key of MIG. When the welding mode is MIG, this indicator will be on.
U
Function key of MMA. When the welding mode is coated manual welding, this indicator will
be on.
W Function key of TIG. When the welding mode is TIG, this indicator will be on.
X
Selection key of display parameters, which can display the parameters of B, E, F, and G
indicators.
Control mode (CNTR)
LOCL (local control)/REMT (remote control)
Material (WIRE)
STEL (steel), CN19 (stainless steel)
Diameter of wire (DIRM)
0.8, 1.0, 1.2, 1.6
Operating mode (TRIG)
2T, 4T, Spot welding
Gas operation (GAS)
CO
2
/MIX
Hot arc (HOTS)
ON/OFF
Striking arc current (HOTI)
10 - 200A
Current rise time (UPSL)
0.1 - 10.0s
Gas pre-flow time (GPR)
0.1 - 20.0s
Slow feeding speed (FDC)
10 - 100%
Slow feeding time (FDT)
0.1 - 1.0 s
Start current (I-S)
100% - 200%
End current (I-E)
10% - 100%
Start time (T-S)
0.1 - 10.0s
End time (T-E)
0.1 - 10.0s
Four-step arc end current (CRAT)
10% - 100%
Current down time (DWSL)
0.1 - 10.0 s
Gas post-flow time (GPO)
0.1 - 20.0 s
Burn-back time (BURN)
0.01 - 1.0 s
Spot welding time (SPOT)
0.1 - 20.0 s
Reset to defaults (DFLT)
NO/YES
3-2. Secondary menu list (different welding modes have different menu items)
9
Содержание MIG 500 DIGITAL
Страница 19: ...CUTTING EDGE WELDING R MANUALE UTILIZZO MIG 380 SYNERGIC PULSE MIG 500 SYNERGIC PULSE...
Страница 38: ...IT www iweld hu 20...
Страница 58: ...EN www iweld hu 20...