Alarm
code
Malfunctions
Cause
Solution
ERR 1000
Problem of
memory chip
Problem of the memory
function of display panel
Shutdown, replacement
of display panel
ERR 0100
Failure of output
insulation
Welding torch output
connected with the ma-
chine casing
Shutdown the welder,
check whether the output
positive electrode is con-
nected with the welder
casing
ERR 0200
Motor current
higher than 5A
Excessive resistance
of wire feeding
Check whether the wire
feeding from the wire reel
is smooth
ERR 0300
Motor current
higher than 3A
Excessive
resistance of wire
feeding
Check whether the wire
feeding from the wire reel
is smooth
ERR 0400
The speed detection
feedback line is not
correct.
The speed detection
feedback line of electrode
feeding machine is broken
or not correct.
Check the speed
detection feedback line
ERR 0001
Inverter
overheating
Welder overheating
Check whether the blower
rotates normally or wheth-
er thermal switch is cut off.
ERR 0002
Input phase
missing
Phase missing of
three-phase AC
Check whether phase
missing happens with
the power cables.
ERR 0003
Long time no-load
output
No-load output
persists
Check the switch of weld-
ing torch
ERR 0004
Long time output
shortcircuit
Long time output
shortcircuit
Check the welding circuit
ERR 0005
VRD failure
Failure of control panel
VRD power source
Check the voltage
feedback line
ERR 0006
Operation of
errors of welder
Personal
operation error
Shutdown and
restart
ERR 0007
Electrode sticks to the
workpiece during manual
welding
The electrode and work-
piece are short circuit for a
long time
Shutdown and
restart
6. Alarm codes
Automatic protection will be triggered in case of abnormal situation happens with
the welder, displaying alarm code, indication, cause and solution as shown in Table:
13