background image

Precautions

Workspace

1. Welding equipment free of dust, corrosive gas, non-

fl

 ammable materials, up to 90% humidity 

for use!

2. Avoid welding outdoors unless protected from direct sunlight, rain, snow, work area tempera-

ture must be between -10 °C and +40°C.

3. Wall to position the device at least 30 inches away.
4. Well-ventilated area to perform welding. 

Safety requirements

Welding provides protection against overvoltage / overcurrent / overheating. If any of the 

above events occurs, the machine stops automatically. However, over- stress damage to the 

machine , keep the following guidelines :

1. Ventilation . When welding a strong current going through the machine , so the machine is 

not enough natural ventilation for cooling . The need to ensure adequate cooling, so the 

distance between the plane and any object around it at least 30 cm . Good ventilation is 

important to normal function and service life of the machine.

2. Continuously , the welding current does not exceed the maximum allowable value. Current 

overload may shorten its life or damage to the machine .

3. Surge banned ! Observance of tension range follow the main parameter table . Welding ma-

chine automatically compensates for voltage , allowing the voltage within permissible limits 

of law. If input voltages exceed the speci

fi

 ed value , damaged parts of the machine .

4. The machine must be grounded! If you are operating in a standard, grounded AC pipeline in 

the event of grounding is provided automatically . If you have a generator or foreign , unfa-

miliar , non-grounded power supply using the machine , the machine is required for ground-

ing connection point earth to protect against electric shock .

5. Suddenly stopping may be during welding when an overload occurs or the machine over-

heats . In this case, do not restart the computer , do not try to work with it right away, but do 

not turn off the power switch , so you can leave in accordance with the built-in fan to cool 

the welding machines .

WARNING!

If the welding equipment is used with the welding parameters above 180 amperes, the standard 

230V electrical socket and plug for 16 amp circuit breaker is not suf

fi

 cient for the required cur-

rent consumption, it is necessary to use the welding equipment with 20A, 25A or even to the 32A 

industrial fuses! In this case, both the plug and the plug socket fork have to be replaced to 32A 

single phase fuse socket in compliance with all applicable rules. This work may only be carried 

out by specialists!

Maintenance

1. Remove power unit before maintenance or repair!
2. Ensure that proper grounding!
3. Make sure that the internal gas and electricity connections are perfect and tighten, adjust if 

necessary, if there is oxidation, remove it with sandpaper and then reconnect the cable.

4. Hands, hair, loose clothing should be kept away under electric parts, such as wires, fan.
5. Regularly dust from the machine clean, dry compressed air, a lot of smoke and polluted air to 

clean the machine every day!

6. The gas pressure is correct not to damage components of the machine.
7. If water would be, for example. rain, dry it in the machine and check the insulation properly! 

Only if everything is all right, go after the welding!

8 When not in use for a long time, in the original packaging in a dry place.

EN-12

Содержание 800CUT125CNC

Страница 1: ...CUTTING EDGE WELDING R HASZN LATI UTAS T S IGBT inverter technol gi s plazmav g g p CUT 85 CNC LCD CUT 125 CNC LCD...

Страница 2: ...t a hegeszt s vagy v g s optim lis karakter nek megtart s ban K rj k hogy a g p haszn lata el tt figyelmesen olvassa el s alkalmazza a haszn lati tmutat ban le rtakat A haszn lati tmutat ismerteti a...

Страница 3: ...oknak megfelel en csatlakoztassa Csupasz k zzel ne rjen semmilyen vezet r szhez a hegeszt k rben mint elektr da vagy vezet k v g Hegeszt skor a kezel viseljen sz raz v d keszty t Ker lje a f st vagy g...

Страница 4: ...ilv nos elektromos h l zathoz kell csatlakoztatni Interferencia eset n tov bbi megel z int zked seket kell hozni p ld ul sz r hasz n lat val t rt n csatlakoz s A r gz tett vhegeszt berendez sekn l a s...

Страница 5: ...21S IP21S 32 1 kg 27 6 kg 745x265x485 745x265x485 Cikksz m FUNKCI K Inverter t pusa vgy jt s THC Magass gszab lyoz s Digit lis LED kijelz CNC kompatibilit s 2T 4T PARAM TEREK Tartoz k plazmapisztoly V...

Страница 6: ...v g pisztoly csatlakoz j ba Csavarja az elektr dot a v g pisztoly v g re gyeng n szor tsa meg s azt n megfelel sorrendben helyezze be a f v k t s v d bor t t Bizonyosodjon meg arr l hogy a megfelel v...

Страница 7: ...s hoz 2 V g ram be ll t gomb Az ramutat j r s val ellent tes ir ny forgat s cs kkenti az ramot az ramutat j r s val meg egyez ir ny forgat s pedig n veli az ramot 3 S r tett leveg ellen rz gomb Nyomja...

Страница 8: ...a a 4T zemm dot v lasztja a v g pisztoly kapcsol j nak egyszeri megnyom s val ind tja a v g si folyamatot a kapcsol ism telt megnyom s val befejezi S r tett leveg ellen rz kijelz 3 Nyomja meg a leveg...

Страница 9: ...darabt l akkor a v g v kialszik V gezze el a v g st Engedje fel a v g pisztoly kapcsol j t ekkor az v kialszik A leveg ezut n m g 30 mp ig ramlik a f v k n kereszt l Hibajelz sek 1 Amikor a g p t lmel...

Страница 10: ...j n t l gyors a mozg s s a darab nincs tv gva ez rt lass tani kell Ha a szikr k f gg legesen a darab fel mutatnak a mozg s sebess ge t l lass s salakosod s n het ez rt a sebess get n velni kell Ha fr...

Страница 11: ...t A g p interf sz k bel nek telep t s t v gezze szakember A telep t s menete 1 Kapcsolja ki a k sz l ket s h zza ki a t pk belt 2 Vegye le a burkolatot az aljzatr l 3 Csatlakoztassa a g p interf sz k...

Страница 12: ...vagy k lf ld n isme retlen nem f ldelt h l zatr l haszn lja a g pet sz ks ges a g pen tal lhat f ldel si ponton kereszt l annak f ldel svezet khez csatlakoztat sa az ram t s kiv d s re 5 Hirtelen le l...

Страница 13: ...a jelenleg hat lyos t rv nyekre szab lyokra s el r sokra A term kkel s annak haszn lat val kapcsolatos rv nyben l v jogszab lyokat meg kell ismerni figyelembe kell venni s be kell tartani Gy rt kijel...

Страница 14: ...HU 14...

Страница 15: ...CUTTING EDGE WELDING R USER S MANUAL Manual Plasma Cutting Machine with IGBT Inverter Technology CUT 85 CNC LCD CUT 125 CNC LCD...

Страница 16: ...environmentally friendly operation By activating the microprocessor control and welding support functions it continuous ly helps maintain the optimum character of welding or cutting Read and use the...

Страница 17: ...ep the working area good ventilated Arc light emission is harmful to eyes and skin Wear proper welding helmet anti radiation glass and work clothes while the welding operation is per formed Measures a...

Страница 18: ...If there is interference additional preventive measures shall be taken such as access with filter in the public power supply system For fixed arc welding equipment the service cables shall be shielded...

Страница 19: ...32 1 kg 27 6 kg 745x265x485 745x265x485 Art Nr FUNCTIONS Inverter Type Arc Ignition THC Torch Height Control LCD CNC Compatibility 2T 4T PARAMETERS Accessories Plasma Torch Max cutting thickness Scarp...

Страница 20: ...the positive output terminal on the front panel of the cutter and tighten the socket Connect the switch plug on the cutting gun with the switch connector of the cut ting gun on the panel Screw the el...

Страница 21: ...T or 4T trigger mode 2 Cutting current knob counterclockwise rotation reduces the current and clockwise rotation increases the current 3 Air check key Press the key if the machine is not connected to...

Страница 22: ...se trigger to start gas touch and lift arc to start Press and release trigger again to stop gas and arc Air check display 3 Press the air check key to check whether the air passage is smooth If the ma...

Страница 23: ...gain Now the machine is ready to use for cutting When you release the cutting switch the arc will be shut down immediately After the arc stopped for about 30 sec you will still have air flow from the...

Страница 24: ...thicknesses if the sparks upturn it indicates the mov ing speed is too fast and the workpiece is not cut through and the moving speed should be slower If the sparks splash vertically to the workpiece...

Страница 25: ...ed by a qualified service technician To install a machine interface cable 1 Turn OFF the power and disconnect the power cord 2 Remove the machine interface receptacle s cover from the rear of the powe...

Страница 26: ...er supply using the machine the machine is required for ground ing connection point earth to protect against electric shock 5 Suddenly stopping may be during welding when an overload occurs or the mac...

Страница 27: ...References to laws rules and regulations are to be understood as related to laws rules and regulations in force at present Manufacturer declares that the above specified product is complying with all...

Страница 28: ...EN 14...

Страница 29: ...napig k telez j t ll st v llalunk a jogszab ly szerint A j t ll s lej rta ut n 3 vig bizto s tjuk az alkatr sz ut np tl st V s rl skor k rje a term k pr b j t Elad t lti ki A v s rl neve Lakhelye V s...

Страница 30: ...ekintet ben jb l kezd dik A j t ll si k telezetts g teljes t s vel kapcsolatos k lts gek a v llalkoz st terhelik A j t ll s nem rinti a fogyaszt jogszab lyb l ered gy k l n sen kell k s term kszavatos...

Страница 31: ...are An Lun Zi tampila i semn tura v nz torului Sec iuni de garan ie a perioadei de garan ie Data raportului Data ncet rii Descriere defect Noul termen de garan ie Numele serviciului Cod de locuri de m...

Страница 32: ...www iweld hu...

Отзывы: