 The  output  of  this  instrument  is  terminated  internally.  Use  a 

waveform  measurement  instrument  with  an  input  impedance 

of at least 1 M

Ω

 Immediately after powering on, this instrument may be subject 

to an appreciable offset drift due to the effect of self-heating. 

To counteract this, allow the instrument to warm up for about 

30 minutes before carrying out measurement. 

 When  performing  continuous  measurements,  it  is  necessary 

to be aware that the offset voltage drifts, depending on factors 

such as the ambient temperature. 

 Under  certain  circumstances,  oscillation  may  occur  if  the 

probe is connected to the PS-52 or PS-54 POWER SUPPLY 

while  the  power  supply  is  on.  This  does  not  indicate  a 

malfunction. 

Oscillation  can  be  stopped  and  operation  restored  to  normal 

by opening and closing the clamp. 

 Acoustic  resonance  may  occur  depending  on  the  level  and 

frequency  of  the  measured  current.  This  does  not  normally 

affect measurements unless a foreign substance such as dust 

is present on the contact surfaces of the sensor head. 

 The reading may be affected by the position within the clamp 

aperture  of  the  insulated  target  conductor  to  be  measured. 

The  insulated  target  conductor  to  be  measured  should  be  in 

the center of the clamp aperture. 

 When  carrying  out  measurement,  press  the  slider  on  the 

sensor  head  until  the  "UNLOCK"  indication  disappears,  and 

hold it until LOCK appears, and check that the opening lever 

is  firmly  locked  and  the  clamp  securely  closed.  Correct 

measurements  cannot  be  performed  unless  the  clamp  is 

securely  closed  and  the  slider  is  pressed  until  LOCK  is 

displayed. 

 At  high  frequencies,  common  mode  noise  may  affect 

measurements  taken  on  the  high  voltage  side  of  circuits.  If 
this  occurs,  reduce  the  frequency  range  of  the  waveform 
measuring  instrument,  or  clamp  onto  the  low-voltage  side  of 
the circuit, as appropriate. 

 

Содержание SS-560

Страница 1: ...Current Probe SS 560 570 Instruction Manual...

Страница 2: ...2021 IWATSU ELECTRIC CO LTD All rights reserved...

Страница 3: ...Names of Parts 12 1 4 Part Functions 12 2 Specifications 15 2 1 Instrument Specifications SS 560 15 2 2 Certification Standards SS 560 16 2 3 Instrument Specifications SS 570 18 2 4 Certification Sta...

Страница 4: ...Memo...

Страница 5: ...pic in the manual marked with the symbol before using the relevant In the manual the symbol indicates particularly important information that the user should read before using the instrument Indicates...

Страница 6: ...y prior notice for improvement or other purposes Unauthorized reproduction of the contents of this manual is strictly prohibited If you have any questions about this instrument contact IWATSU or our s...

Страница 7: ...very dangerous for targets to be measured that use high current Do not use this instrument to measure exposed conducting lines This may result in electric shock short circuiting or equipment damage T...

Страница 8: ...this manual for the recommended power supply of our company When handling power cables and sensor cables This may result in fire electric shock or equipment damage If the power cord is damaged contact...

Страница 9: ...trument is connected and then detach this instrument from the insulated target conductor to be measured After that contact IWATSU or our sales distributors for repair Do not put any metallic or flamma...

Страница 10: ...s the earth potential this instrument the equipment and the circuit to be measured must be damaged because the equipment that connects this instrument is connected to a ground Moreover there must be d...

Страница 11: ...ount of time for the unit to cool before resuming normal operation At high temperatures the overcurrent protection circuit in the unit may cause the protective interlock to operate at current levels t...

Страница 12: ...dew condensation Storage humidity below the moisture amount of 80 RH Do not leave this instrument in wet or dusty environments This may result in electric shock fire or equipment damage For your safe...

Страница 13: ...applied during transportation possibly causing a fire If you do not have a proper packing or shock absorbing material for transportation contact IWATSU or our sales distributors If transportation is...

Страница 14: ...ment to be repaired clearly write the instrument name serial number in the label on the rear of this instrument description of the failure and the name division and telephone number of the responsible...

Страница 15: ...insulated target conductor to be measured allows the current waveform to be easily captured 1 2 Features Highly accurate current detection Easy current measurement Broadband frequency bandwidth SS 560...

Страница 16: ...to be measured and carries out the actual current measurement It is a precision assembly including a molded component a ferrite core and a Hall element It may be damaged if subjected to sudden changes...

Страница 17: ...adjustment 8 Output connector The current waveform of the measured conductor is output at a constant rate 0 01 V A Connect to the BNC input connector of the waveform measuring instrument The output of...

Страница 18: ...1 Overview 14 Memo...

Страница 19: ...Equivalent to 25 mArms or less for measuring instrument with 20 MHz bandwidth Input impedance Typical characteristics shown in Fig 3 Temperature characteristic of sensitivity 2 or less Input 55 Hz 150...

Страница 20: ...cord lengths Sensor cable 2 0 m 0 1 m Power cord 1 0 m 0 1 m External dimensions Sensor part 176 W X 69 H X 27 D mm 2 mm Terminator part 27 W X 55 H X 18 D mm 2 mm Weight 500 g 20 g Accessories Hard...

Страница 21: ...2 Specifications 17 Fig 1 Frequency characteristics SS 560 Typical characteristics Fig 2 Derating according to frequency SS 560 Fig 3 Input impedance SS 560 Typical characteristics...

Страница 22: ...rument with 20 MHz bandwidth Input impedance Typical characteristics shown in Fig 6 Temperature characteristic of sensitivity 2 or less Input 50 Hz 500 Arms within a range of 0 to 40 C Maximum power c...

Страница 23: ...0 m 0 1 m Power cord 1 0 m 0 1 m External dimensions Sensor part 176 W X 69 H X 27 D mm 2 mm Terminator part 27 W X 55 H X 18 D mm 2 mm Weight 500 g 20 g Accessories Hard case 1 Instruction manual 1...

Страница 24: ...2 Specifications 20 Fig 4 Frequency characteristics SS 570 Typical characteristics Fig 5 Derating according to frequency SS 570 Fig 6 Input impedance SS 570 Typical characteristics...

Страница 25: ...to be measured This instrument is made for use with PS 52 or PS 54 POWER SUPPLY It is possible to use a power supply other than PS 52 and PS 54 provided that the connector and pin assignments match an...

Страница 26: ...this instrument is terminated internally Use a high impedance input to the measuring instrument With an input impedance of 50 accurate measurement is not possible Depending on the current value being...

Страница 27: ...lling out the connector Forcibly pulling the connector without releasing the lock or pulling on the cable can damage the terminator When inputting the signal into input terminals other than BNC connec...

Страница 28: ...lectric current direction mark displayed in sensor assembly point corresponds to the direction of current flow through the insulated target conductor to be measured and so that the insulated target co...

Страница 29: ...t value to be measured Confirm that the total current consumption of this instrument does not exceed the current of 600 mA See Figure 7 for SS 560 or Figure 8 for SS 570 Fig 7 Current consumption vs c...

Страница 30: ...remove the input immediately remove the sensor from the insulated target conductor to be measured or reduce the input current to zero Wait until the sensor has had sufficient time to cool before resu...

Страница 31: ...ot allow current level to exceed the specified limit of the operating range To avoid damage to this instrument when opening the clamp of the probe be sure to operate with the slider Do not place any u...

Страница 32: ...ce may occur depending on the level and frequency of the measured current This does not normally affect measurements unless a foreign substance such as dust is present on the contact surfaces of the s...

Страница 33: ...ied to the output this is not a fault Accurate measurement may be impossible in locations subject to strong external magnetic fields such as transformers and high current conductors or in locations su...

Страница 34: ...ry if Probe power option DS 579 Use the instrument within the range where the total of the current consumption of it is 750mA or less of product of our company that can be used as power supply for pro...

Страница 35: ...MEMO...

Страница 36: ...erseas Sales Sect Sales Dept No 2 Address 1 7 41 Kugayama Suginami ku Tokyo 168 8501 Japan Phone 81 3 5370 5483 Facsimile 81 3 5370 5492 Web Site http www iti iwatsu co jp index_e html E mail info tme...

Отзывы: