Chapter 5 Specifications
24
Chapter 5 Specifications
5.1 Specifications
Basic specifications
SS-293S/L
SS-294S/L
SS-295S/L
SS-296S/L
Sensitivity [mV/A]
5
2
1
0.5
Peak current [kA]
1.2
3
6
12
Peak di/dt [kA/
μs]
S:60/L:32
80
80
80
Absolute maximum di/dt
Peak [kA/μs]
80
80
80
80
RMS [kA/μs]
3.0
3.0
3.0
3.0
Frequency bandwidth
f
L
to 20 MHz [
−3 dB] SS-29xS
f
L
to 10 MHz [
−3 dB] SS-29xL
f
L
: Low frequency cutoff
Low frequency cutoff [Hz]
1
0.8
0.6
0.4
Noise [mV rms]
3.5
2.0
1.4
1.2
Sensitivity accuracy
±2%
At the center of the coil loop with sensor part temperature
of −10
C to +70
C
*: Add an error of ±250 ppm/
C when the temperature is
−10
C or less or +70
C or more.
Output
Maximum voltage range: ±
6 V (load ≥ 100 kΩ)
Connector
BNC
Linearity
±0.05% of full scale
Zero point adjustment range
±300 mV or more
Sensor part
Coil length
SS-29xS: 300 mm ±10 mm, SS-29xL: 700 mm ±10 mm
Wire rod diameter at coil part
8.5 mm (max.)
Maximum rating voltage
between ground
10 kV peak (resisting voltage guarantee range:
Refer to Section 4.3.2)
Sensor cable length
3.0 m ±100 mm
Operating temperature range
−40 to 125
C (including sensor cable
)
General specification
Dimensions
Approx. 80 (W) × 165 (H) × 35 (D) mm
(excluding protrusions)
Weight
SS-29xS: Approx. 0.48 kg, SS-29xL: Approx. 0.50 kg
Power supply
Four AA dry batteries
Note 1
Battery longevity
Note 2
Approx. 30 hours (when alkaline batteries are
used)
Содержание SS-293L
Страница 1: ...Rogowski Coil Current Probe SS 293S 293L 294S 294L SS 295S 295L 296S 296L Instruction Manual...
Страница 2: ...2015 IWATSU TEST INSTRUMENTS CORPORATION All rights reserved...
Страница 4: ...Memo...
Страница 16: ...Chapter 2 Names and Functions of Parts 12 Chapter 2 Names and Functions of Parts 2 1 Main Unit...
Страница 30: ...Chapter 5 Specifications 26 5 2 Appearance 1 Main Unit Unit mm...
Страница 31: ...Chapter 5 Specifications 27 2 Rogowski Coil Sensor Part Unit mm...
Страница 32: ...Chapter 5 Specifications 28 Memo...
Страница 34: ...SS 293S 293L 294S 294L 295S 295L 296S 296L...