Capter2
Name
and Function of Each Part (Outline)
Curve Tracer CS-5000 Series Instruction Manual
2-15
Table 2.11 Name and function of each part on test fixture CS-304
The terminal since
⑩
is terminals in the patch panel of test fixture CS-304 among in the table below.
When the test adaptor is used, the patch panel should be necessary, and the terminal since these
⑩
be connected.
No.
Name
Description
Ref.
①
COLLECTOR SUPPLY HIGH
VOLTAGE
It is an output terminal of the collector supply at the
HIGH VOLTAGE mode.
Section 3.7
②
COLLECTOR SUPPLY SENSE
It is a Kelvin Sense terminal of the collector supply
Section 3.7
③
COLLECTOR SUPPLY HIGH
CURRENT
It is an output terminal of the collector supply at the
HIGH CURRENT mode.
- The screw terminal (It is a big connector terminal in
Figure 2.14) is used at the measurement that
should set MAX PEAK CURRENT to 1.5 kA.
- When measuring in the situation except that MAX
PEAK CURRENT is not 1.5 kA, either of screw
terminal / banana terminal can be used.
- HC cable option CS-007 can be used for the
connection of the thing to be measured and this
terminal.
Section 3.7
④
EMITTER/SOURCE/CATHODE
It is an output terminal in emitter/source/cathode at
the HIGH CURRENT mode.
- The screw terminal (It is a big connector terminal in
Figure 2.14) is used at the measurement that
should set MAX PEAK CURRENT to 1.5 kA.
- When measuring in the situation except that MAX
PEAK CURRENT is not 1.5 kA, either of screw
terminal / banana terminal can be used.
- HC cable option CS-007 can be used for the
connection of the thing to be measured and this
terminal.
Section 3.7
⑤
EMITTER/SOURCE/CATHODE
SENSE
It is a Kelvin Sense terminal of emitter / source /
cathode.
Section 3.7
⑥
BASE/GATE
It is an output terminal of the step signal.
Section 3.6
⑦
BASE/GATE SENSE
It is a Kelvin Sense terminal of the step signal.
Section 3.6
⑧
AUX
Output terminal of external output voltage
Section 3.11.6
⑨
AUX GROUND
Ground terminal of external output voltage
Section 3.11.6
⑩
COLLECTOR SUPPLY
、
HIGH
VOLTAGE OR HIGH CURRENT
It mitigates the shock when the upper cover is
closed.
Section 3.7
⑪
COLLECTOR SUPPLY SENSE
It connects with the
①
HIGH VOLTAGE or
③
HIGH CURRENT.
Section 3.7
⑫
EMITTER/SOURCE/CATHODE
It connects with the output terminal in emitter /
source / cathode of
④
.
Section 3.7
⑬
EMITTER/SOURCE/CATHODE
SENSE
It connects with the Kelvin Sense terminal of
⑤
.
Section 3.7
⑭
BASE/GATE
It connects with the output terminal in the step signal
of
⑥
.
Section 3.6
⑮
BASE/GATE SENSE
It connects with the Kelvin Sense terminal of
⑦
.
Section 3.6
⑯
BASE/GATE 1k
Ω
It is connected internally through the base terminal
of
⑰
and the resistance of 1kΩ.
Section 3.3
⑰
ADAPTER EXCLUSIVE USE
These are terminals that install the test adapter.
Section 3.3
Содержание CS-5000 Series
Страница 1: ...Instruction Manual Curve Tracer CS 5000 series CS 5100 CS 5200 CS 5300 CS 5400 ...
Страница 2: ...Ⓒ 2013 IWATSU ELECTRIC CO LTD All rights reserved ...
Страница 16: ...0 4 Memo ...
Страница 48: ...Capter2 Name and Function of Each Part Outline 2 30 Curve Tracer CS 5000 Series Instruction Manual Memo ...
Страница 210: ...Capter4 Characteristics Measurement 4 40 Curve Tracer CS 5000 Series Instruction Manual Memo ...
Страница 214: ...Capter5 Daily Maintenance and Calibration 5 4 Curve Tracer CS 5000 Series Instruction Manual Memo ...