18
Inspection
Perform daily inspection to keep pump performance and safety.
Daily inspection
Check for a leak or any other abnormality during operation. Upon sensing abnormality, stop operation immedi-
ately and remove problems according to "Troubleshooting".
Wear part list
To run the pump for a long period, wear parts need to be replaced periodically or when pump performance has
reduced. Contact your distributor for detail.
Part names
Q’ty
Estimated life
Remarks
O ring
2
Kalrez®
AS568-129
Valve gasket
10
PTFE
Valve guide
4
PTFE
Valve
4
RUBY
Valve seat
4
PCTFE
Valve case
2
PCTFE
Inspection
Содержание PDS-105 RA