Troubleshooting

This section describes troubleshooting, inspection, specification and dimensions.

 Points to be observed

Observe the following points during maintenance work.
• 

 

Follow instructions in this manual for replacement of wear parts. Do not disassemble the 

pump beyond the extent of the instructions.

• 

 

Always wear protective clothing such as an eye protection, chemical resistant gloves, a 

mask and a face shield during disassembly, assembly or maintenance work. The spe-

cific solution will dictate the degree of protection. Refer to MSDS precautions from the 

solution supplier.

•  Solution in the discharge line may be under pressure. Release the pressure from the 

discharge line before disconnecting plumbing or disassembly of the pump to avoid solu-

tion spray.

• 

 

Risk of electrical shock. Be sure to turn off power to stop the pump and related devices 

before service is performed.

Troubleshooting

First check the following points. If the following measures do not help remove problems, con-

tact your distributor.

States

Possible causes

Solutions

The pump does not 

run.

Faulty wiring

• 

 

Correct wiring and resume operation.

Power-supply voltage is too low.

• 

 

Observe the rated voltage of the pump.

Motor failure

• Check the motor. Replace as necessary.*

Liquid can not be 
pumped up.

Air ingress through a suction line.

• Reroute piping.

A failed O ring seal.

• Check O rings. Replace as necessary.*

Foreign matters are stuck in the flow 
path in the pump head or piping.

• 

 

Dismantle, inspect and clean the pump 
head or piping. Replace as necessary.*

Malfunction of an air-operated valve.

• 

 

Check the valve. Replace as necessary.

A check valve (pump head valve) is 
stuck on a valve seat.

• 

 

Dismantle, inspect and clean the valve. 
Replace as necessary.*

A flow rate fluctuates.

Foreign matters are stuck in a pipe 
line.

• 

 

Dismantle, inspect and clean the line. 
Replace as necessary.

Air stays in the pump head or in a pipe 
line.

• 

 

Expel air.

A check valve (pump head valve) is 
stuck on a valve seat.

• 

 

Dismantle, inspect and clean the valve. 
Replace as necessary.*

A failed O ring seal.

• Check O rings. Replace as necessary.*

A hydraulic fluid leak

• Check for a leak. Replace as necessary.*

Motor failure

• Check the motor. Replace as necessary.*

Sensor signal is not 
outputted.

Faulty wiring

• 

 

Correct wiring and resume operation.

Sensor failure

• 

 

Check a sensor. Replace as necessary.*

Solutions marked with * are conducted by us.

Maintenance

Содержание PDS-105 RA

Страница 1: ...866228 FAX 7503866278 Singapore IWAKI Singapore Pte Ltd TEL 65 63162028 FAX 63163221 China GFTZIWAKIEngineering Trading Guangzhou TEL 86 2084350603 FAX 2084359181 Spain IWAKI Iberica Pumps S A TEL 34...

Страница 2: ...immediately contact your distributor a Check if the delivery is correct Check the nameplate to see if the information such as model codes and production number are as or dered b Check if the delivery...

Страница 3: ...Suction process 10 Identification codes 11 Installation 12 Before installation 12 Installation Piping Wiring 13 Installation 13 Piping 13 Wiring 14 A connector signal 14 B connector motor 14 Operation...

Страница 4: ...Inspection 18 Daily inspection 18 Wear part list 18 Specification Outer dimension 19 Specification 19 Pump 19 Stepping motor 20 Encoder RB type 20 Home sensor 20 Pressure sensor 20 Outer dimension 21...

Страница 5: ...ymbol accompanies each precaution suggesting the use of Caution Prohibited actions or specific Requirement Indicates mishandling could lead to personal injury or prop erty damage CAUTION Caution marks...

Страница 6: ...in failure or injury Use this product in specified conditions only Do not modify the pump Alterations to the pump carries a high degree of risk It is not the manufac turer s responsibility for any fai...

Страница 7: ...ure water or the liquid to be delivered before the start of operation Static electricity When low electric conductivity liquids such as ultra pure water and fluor inactive liquid e g FluorinertTM are...

Страница 8: ...not waterproof Do not operate the pump while wet with solu tion or water Failure or injury may result Immediately dry off the pump if it gets wet Do not close discharge line during operation Solution...

Страница 9: ...s reciprocates Principle of operation The bellows expands and contracts as the ball screw reciprocates The reciprocating motion of the bellows compresses or expands the shape of the tubephragm via hyd...

Страница 10: ...10 Introduction Suction process IN...

Страница 11: ...ion 1 Pump c Flow rate 05 5 0ml shot max discharge capacity d Drive unit RA Compact type RB With an encoder line driver e Wet end O ring K Kalrez f Pressure sensor P Positive pressure sensor 0 1000kPa...

Страница 12: ...normal or dangerous conditions suspend operation immediately and inspect solve problems Do not install the pump in a flammable atmosphere Before installation A driver in a user s PLC and other related...

Страница 13: ...indoors Allow sufficient space around the pump for easy access and maintenance Mounting position Install the pump as close to a supply tank as possible in a flooded suction system Mounting direction A...

Страница 14: ...r output D Encoder B phase Line driver output E GND common F Sensor output open collector G 5 24VDC home sensor power H 5VDC encoder power The RA type does not equipped with the encoder B connector mo...

Страница 15: ...ome sensor is at the L GND level Number of pulses Discharge capacity RV Calculated flow rate Number of input pulses 1ml 2400 2ml 4800 3ml 7200 4ml 9600 5ml 12000 The above data is based on the assumpt...

Страница 16: ...vis cosity and piping conditions and may overload the bellows Do not set a discharge speed too fast Suction pressure may be too low negative and trigger cavitation depending on operating conditions s...

Страница 17: ...wiring Correct wiring and resume operation Power supply voltage is too low Observe the rated voltage of the pump Motor failure Check the motor Replace as necessary Liquid can not be pumped up Air ingr...

Страница 18: ...medi ately and remove problems according to Troubleshooting Wear part list To run the pump for a long period wear parts need to be replaced periodically or when pump performance has reduced Contact yo...

Страница 19: ...pressure may be too low negative and trigger cavitation depending on operating conditions such as liquid viscosity piping layouts and suction speed max 3ml sec Adjust the suction speed as necessary 2...

Страница 20: ...on current 60mA or below Detection Incremental Number of output pulses 500 Output phase 2 phase A and B Output type Line driver Home sensor Items Spec Manufacturer OMRON Model EE SX670A Supply voltage...

Страница 21: ...21 Specification Outer dimension PDS 105R A B Specification Outer dimension IN 1 4 PFA tube OUT 1 4 PFA tube 60 100 182 13 5 50 100 189 213 5 105 182 7 161 175 4 4 30 4 4 30 R 2000 23...

Страница 22: ...2 In port unit 1 PFA 3 Out port 1 PFA 4 In connecting port 1 PFA 5 Out connecting port 1 PFA 7 O ring 2 Kalrez AS568 129 10 Valve cap 2 PP 11 Valve seat 4 PCTFE 12 Valve guide 4 PTFE 13 Valve 4 RUBY...

Страница 23: ...23 Specification Specification Outer dimension...

Страница 24: ...866228 FAX 7503866278 Singapore IWAKI Singapore Pte Ltd TEL 65 63162028 FAX 63163221 China GFTZIWAKIEngineering Trading Guangzhou TEL 86 2084350603 FAX 2084359181 Spain IWAKI Iberica Pumps S A TEL 34...

Отзывы: