![IWAKI PUMPS MXM Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/iwaki-pumps/mxm-series/mxm-series_instruction-manual_2098029033.webp)
3. Pull out the impeller unit + the magnet capsule
assembly. Be careful not to scratch each part.
Note that the magnetic force of the magnet cap-
sule assembly is strong. Keep it free from metal
pieces or powder. Do not scratch any sliding or
sealing surfaces.
CAUTION
The magnetic force of the magnet cap-
sule assembly is powerful. Be careful not
to catch the finger in the impeller unit and
the assembly.
4. Insert a flat-head screwdriver between the rear
casing and the motor bracket. And then pull the
rear casing forward while lifting it slightly up.
If the spindle stays on the front casing, remove it
from the front casing. Fit the spindle to the rear
casing with the rear thrust mated at the end.
Always check the rear thrust is mated to the spin-
dle before fitting spindle.
If the spindle can not be removed, warm a spin-
dle connection with hot water (about 90
°C
) for
5 minutes and try again. Be careful not to be
scalded.
CAUTION
Be careful not to damage the sealing sur-
face between the front casing and rear
casing where crushes the O ring.
- 31 -
Impeller
Magnet capsule
Maintenance
Rear casing
Spindle
Содержание MXM Series
Страница 6: ...4 Outline 1 Unpacking Inspection 5 2 Model codes 6 3 Operating conditions 7 4 Part names 8...
Страница 15: ...13 Installation 1 Before installation 14 2 Pipework 15 3 Wiring 17 4 Protection equipment 18...
Страница 21: ...19 OPERATION 1 Before operation 20 2 Operation 21 3 Shutdown 22...
Страница 25: ...23 Maintenance 1 Troubleshooting 24 2 Maintenance Inspection 26 3 Disassembly Assembly 29 4 Spare Wear parts 36...
Страница 41: ...39 Maintenance...
Страница 42: ...40...
Страница 43: ...41...