- 25 -
Maintenance
Troubles
Symptom
Cause
Point to be checked
&
Countermeasures
When a discharge
valve is closed.
When a discharge
valve is opened.
The motor is
overheated.
• Voltage has dropped
greatly.
• Overload
• Surrounding tempera-
ture is too high.
• Check voltage or fre-
quency.
• Check specific gravity
and viscosity of liquid.
• Keep a good ventila-
tion.
A flow rate
has dropped
suddenly.
Vacuum is high.
• A suction line clogs
with foreign matters.
• Remove foreign mat-
ters.
The pump
vibrates.
• The base is not
anchored firmly.
• Anchor bolts are loose.
• Cavitation occurs.
• Pump bearing is worn
or failed.
• Magnet capsule or
impeller is broken.
• Dynamic balance of
drive magnet is upset.
• Motor bearing is worn.
• Fix the base.
• Retighten the bolts.
• Remove the cause of
cavitation.
• Replace as necessary.
• Replace as necessary.
• Investigate problems
and replace as neces-
sary.
• Replace bearing or a
motor unit.
Содержание MXM Series
Страница 6: ...4 Outline 1 Unpacking Inspection 5 2 Model codes 6 3 Operating conditions 7 4 Part names 8...
Страница 15: ...13 Installation 1 Before installation 14 2 Pipework 15 3 Wiring 17 4 Protection equipment 18...
Страница 21: ...19 OPERATION 1 Before operation 20 2 Operation 21 3 Shutdown 22...
Страница 25: ...23 Maintenance 1 Troubleshooting 24 2 Maintenance Inspection 26 3 Disassembly Assembly 29 4 Spare Wear parts 36...
Страница 41: ...39 Maintenance...
Страница 42: ...40...
Страница 43: ...41...