- 18 -
Installation
■ Foundation work
•
Installation area should be larger than the footprint
of the pump. Or a plastic base may break due to a
concentrated load.
• If piping vibrates sympathetically with the pump in
operation, provide an expansion joint between the
pump and the piping to reduce vibration.
■ Tightening torque between the pump and pipework
Connect the pump to pipework via inlet and outlet flanges according to the tightening torque below. The table is
based on use of metal pipe flanges with rubber gaskets. Tighten bolts diagonally at even torque.
Model
Bolt size
Tightening torque
MX-F250/-F251/-F400/-F401/-F402/-F403
M16
20N•m
■ Piping load and momentum
Try not to apply a heavy load to the inlet and outlet flanges. Permissible piping weight and moment to the pump are as
below.
Z
Y
X
Z
Y
X
Shim
Foundation bolt
Liner
Concrete
Base