- 17 -
Installation
14
1
2
12
3
4
12
15
5
6
7
2
16
2
10
11
12
2
13
15
17
2
9
1. Discharge pipe
( Support pipework to keep the pump free of
piping weigh.)
2. Gate valve
3. Check valve
4. Pressure gauge
5. Motor
6. Pump
7. Air vent/ priming line
9. Drain ditch
10. Vacuum gauge
11. Suction pipe (Pipe diameter: D)
( Horizontal sections should be shortest and
laid on a rising gradient of 1/100 toward the
pump)
12. Pipe support
13. Suction pipe (Pipe diameter: D)
14. 2D or 500mm or more
15. Expansion joint
16. Flushing line (Discharge side)
17. Flushing line (Suction side)
Installation location
• Install the pump as close to a supply tank. Keep a liquid level in the tank higher than the pump at any time (flooded
suction application).
• In case the pump is installed above a liquid level (suction lift application), lay on a priming line and mount a foot
valve to the bottom of a suction line.
NOTE: The maximum suction lift varies with liquid characteristics, specific gravity, liquid tempera-
ture and suction line length. Contact us for detail.
Outdoor use motors (Indoor use motors can not be installed out of doors)
Outdoor use motors can also be used in doors. Protect the motor and electrical power distribution equipment from
possible damage due to an accidental outflow or act of providence.
Installation space
• Select a flat and a rigid floor/foundation where is free from vibration and contortion.
• Keep a wide working area for convenience in installation and maintenance.
CAUTION
Fix the pump firmly. Support piping so as not to directory weigh on the pump.
■ Installation
Arrange pump and pipework based on the following piping layout for a long period of operation.