17
—
⑪
Performance and Sizes
■
Performance
Model of Pump Diameter
Maximum
Flow rate
(
ℓ
/min)
Maximum
Discharge
Pressure
(MPa)
Attainable
Degree of
Vacuum
kPa (abs.)
Motor Specifications
Weight
(kg)
Rated
Voltage
(V)
Rated
Current
(A)
Rated
Output
(W)
Type
MDG-M4S6B115L
1/4NPT
4/4.8
0.6
5.33
1
φ
115
1.5/1.7
100
2P
Induction
Motor
Capacitor
Run
Type
7.9
MDG-M4S6B220
1
φ
220~240
0.70/0.84
MDG-M4T6B115L
3.8/4.6
8.00
1
φ
115
1.5/1.7
MDG-M4T6B220
1
φ
220~240
0.70/0.84
MDG-M4T6B220H
1.4/1.5
150/180
8.2
〔
Note
〕
1. Above is the performance on a test of clean water at 25ºC.
(The discharge changes depending on the temperature of liquid handled.
Further information will be supplied on request.)
2. The pumps can be used in an ambient temperature between 0 and 40ºC.
3. Maximum operating noise is 60dB or below.
(1 m away from the front of pump, A scale)