- 25 -
Warning
•
Magnetic force is very strong. Pay attention when you handle the magnet capsule or driving magnet so that
fingers can not be injured by attraction of magnets.
•
The persons who are assisted by electronic devices such as pacemakers etc. are prohibited to approach the
magnet capsule and drive magnet.
Caution
•
Magnetic force is very strong. Pay attention so that iron pieces or powder can not be attracted to the magnet
capsule or drive magnet.
•
Do not approach the magnetic card to the pump not to break the data.
3. Disassembly and assembly
MDF-L250, 401
MDF-L422, 423
and 425
Front casing
Front casing
Drain cap
■
Disassembly
(1) Disassemble only after thoroughly washing out the
liquid inside the pump by use of flushing piping,
remove the cap to discharge the liquid from the pump.
Then, clean the inside of the pump.
Warning
Wear protectors (goggles, rubber gloves, etc.).
Certain liquids are dangerous. They may hurt your
eyes and skin.
(2) Remove the front casing from the foot support
.
Remove the hex socket bolts (or hex bolts) and take
out the front casing from the foot support.
Be careful with the spindle which remains pressed-fit
in the front casing.
Caution
Strong impacts may crack the spindle or casing.
Do not hit them with a tool.
*
The spindle is integrated with the rear casing, not
pressed into the front casing.
* During disassembly, discharge the liquid from the
casing and clean the inside of the pump.