19
Inst
allat
ion
/LTXLGOLQHSLSLQJ
Discharge line
Ŷ3XOVDWLRQUHGXFWLRQ
The pipe resistance increases as a discharge line becomes longer or the number of bends increases. In
order to decrease pipe resistance, install a dampener and minimizes pulsation.
:KHQVHQGLQJDOLTXLGXSYLDDULVHUSLSHLQVWDOODFKHFNYDOYHDVZHOODVDGDPSHQHU
Ŷ:KHQLQVWDOOLQJDYDOYHRQWKHGLVFKDUJHOLQH
Select a valve with an orifice equal to or larger than pipe I.D. A valve with a small orifice may increase the pipe
resistance or easily be clogged with crystals. Always open valves during operation. Do not close the valve until
the discharge pressure reaches "0" after the pump is stopped.
NOTE
'RQRWFORVHDGLVFKDUJHYDOYHULJKWDIWHUVWRSSLQJWKHSXPS,PSDFWSUHVVXUHPD\GHIRUPWKHEHOORZV
Ŷ)LOWUDWLRQFLUFXODWLRQ
&KHFNDILOWHULQJDUHDILOWHULQJSHUIRUPDQFHDQGHIIHFWVRQWKHIORZEHIRUHVHOHFWLQJDF\FOHILOWHU$GHVLUHG
IORZPD\QRWEHREWDLQHGLIVHOHFWLRQLVZURQJ
NOTE
:HWWKHILOWHUEHIRUHXVH$GHVLUHGIORZPD\QRWEHREWDLQHGLIWKHILOWHULVGU\)LOWHUGULHVXSLILWLVXQXVHGIRU
DORQJSHULRG5HDGWKHLQVWUXFWLRQPDQXDORIWKHILOWHUIRUGHWDLOV
Ŷ)LOWUDWLRQGLVFKDUJHOLQHHQG
,QVWDOODILOWHURUVWUDLQHULQDGLVFKDUJHOLQHQRWWRUHOHDVHIRUHLJQPDWWHUVRUZDIHUIUDJPHQWV7KHILOWHURU
VWUDLQHUVKRXOGQRWLQFUHDVHSLSLQJUHVLVWDQFHWRRPXFKREVHUYHWKHPLQLPXPFRPSRVLWHHIIHFWLYHFURVVVHF
WLRQDOGLDPHWHU
Ŷ'HSUHVVXUL]DWLRQDWSXPSVWRS
:KHQVWRSSLQJWKHSXPSEHVXUHWRUHOHDVHGLVFKDUJHSUHVVXUHE\RSHQLQJWKHILOWHUWKHDLUYHQWYDOYHRU
WKURXJKDUHWXUQFLUFXLW
NOTE
6WRSSLQJWKHSXPSZLWKRXWUHOHDVLQJGLVFKDUJHSUHVVXUHPD\GHIRUPWKHEHOORZV
Содержание FW-20H