44
Pump operation
The start/stop of the pump is controlled by the LPC-1 controller in MANU mode or a user PLC
in AUTO mode.
Points to be observed
Before operation in your system, conduct a trial run with pure water (or chemical liquid) to
flush out particles or to measure metal ion level.
Pump model selection
Select a pump model which comes under the control of the LPC-1 controller.
Select "1. PUMP MODEL" and push the
ENTER key.
Select "FLP-75" and push the ENTER key.
"FLP-75 SELECT OK!" appears on the screen.
* Always choose a correct model. Otherwise, malfunc-
tion results.
* The controller refuses the start of operation and asks
for the selection if a model hasn't been selected, yet.
Check if the selection is correct and push
the ENTER key.
The main menu shows up.
* Once you have chosen the correct pump model, you
can skip this selection step as long as the same con-
troller is used, even after the LPC-1 controller power is
turned off.
* If you have changed the model selection, all the later
related settings return to the default.
2
1
3
Pump operation