23
In
st
al
la
tion
Pipework
Mount a check valve at the discharge tube end.
*
The CAN check valve has R1/2 and R3/8 thread connections as well as a ø9
tube connection. Cut off unnecessary sections before use.
CAN check valve
*
The CBN check valve of which the both ends are tube connections is also
available. Contact us or your nearest distributor.
CBN check valve
NOTE
Periodically clean or replace a check valve with new one for the prevention of crystal
clogging, especially when using sodium hypochlorite.
Tubing layout
Flooded suction application
Suction lift application
NOTE
Flooded suction is recommended when handling a gaseous liquid such as sodium
hypochlorite.
1
Check valve
Accumulator/Chamber
Pump
Pump
Accumulator/Chamber
Air vent line
Air vent line
Check valve
Relief valve
Relief valve
Outer dia ø9
R1/2
R3/8