■ Basic displays & Pump states
Display info
ON LED lights
ON LED flushes
(in sync with each shot)
A wait state in MAN mode:
The display shows the MAN
speed in spm.
Operation in MAN mode:
A current spm flashes (not in
sync with a pump shot).
―
Operation in EXT mode:
A current spm flashes (not in
sync with a pump shot).
STOP signal is entered in MAN
mode. If the spm flashes, it
means the pump is just suspend
-
ed and will restart as the signal is
turned OFF.
―
STOP signal is entered in EXT
mode. If the spm flashes, it
means the pump is just suspend
-
ed and will restart as the signal is
turned OFF.
―
―
Keypads are locked and any key
operation is cancelled.
Keypads are locked in a sus
-
pended MAN/EXT mode with the
STOP signal.
―
The pump is in maintenance
mode. When extending the dia
-
phragm, the display flashes.
―
Part names
Represents the pump
is receiving the STOP
signal.
Represents keypads are locked.
Represents the pump
is in EXT mode.
Shows a pump speed in spm. The spm
flashes during operation in MAN and EXT
modes. The indication changes to "- - -"