11
MAINTENANCE AND REPAIR
Your Power Station PS-300 is a high-quality device which operates trouble-free for many years if handled with care and
maintained properly. Should failures occur, however, please do not try to open the device to repair it yourself. Even in
switched-off condition there may be hazardous voltages in the interior of the device. The device may also be damaged by
improper handling. Please contact an authorised expert or our service instead.
CLEANING
•
Never immerse the device into water!
•
Disconnect the device from both the charger and the charging adapter as well as from any consumers before cleaning.
•
Clean the outside of the Power Station PS-300 only with a soft, dry cloth or with a soft brush.
Important! Never use aggressive detergents or chemical products, as this might damage the housing
surface.
TECHNICAL SPECIFICATIONS
General
Battery type:
12 V 20 Ah AGM (lead acid-VRLA)
Accu Trainer Pb:
Input: 100 - 240 V AC
Output: 13.8 V DC/max. 1.5 A
Charging adapter:
12 V DC, 12 – 14.4 V DC max. 5 A
Fuse for charging adapter:
F5A; 6.3 x 32 mm
Cable length for 12 V charging adapter:
150 cm
Dimensions:
240 x 145 x 215 mm
Weight:
10.4 kg
12 V DC output
Max. output current:
10 A
Max. time of operation at 10 A:
85 min. (with full battery)
Idle current:
4 mA
Deep discharge protection:
yes
Fuse:
T10A (accessible from outside)
230 V AC output
Output voltage:
225 V AC (+5/-8 %) 50 Hz
Continuous output rating:
max. 300 VA (cos ϕ > 0.8)
Duration of output current:
1.4 A
eff
Max. time of operation at 300 VA:
30 min. (with full battery)
Idle input power:
3.6 VA
Deep discharge protection:
yes
Overload cut-off device:
yes
ENVIRONMENTAL PROTECTION NOTE
At the end of its useful life, this product must not be disposed of together with normal household
waste, but has to be dropped off at a collection centre for the recycling of electrical and electronic
devices. This is indicated by the symbol on the product, on the instruction manual or on the
packaging. The materials of which this product is made are recyclable pursuant to their labeling.
With the reuse, the recycling of the materials or other forms of scrap usage you are making an
important contribution to the protection of the environment. Please ask your local administration
office for the appropriate disposal center.
Technical are specifications subject to change. We assume no liability for typographical errors. V3_07/2015
IVT Innovative Versorgungs-Technik GmbH, Dienhof 14, D-92242 Hirschau
Tel: 09622-719910; Fax: 09622-7199120;
;
www.ivt-hirschau.de