20
FOR THE USER
The menu shows the temperature in the heating system’s return, i.e. the
water from the radiators back to the heat pump in heating mode. This
temperature varies depending on the outdoor temperature.
The menu shows the outdoor temperature. Some deviation may occur due
to thermal radiation from the house to the installed outdoor sensor.
The menu is only shown when you have a hot water heater connected to the
system. The menu shows the temperature in the lower section of the outer
container in the hot water heater. The temperature is approximately 5ºC
lower than the temperature of the hot water inside the inner container.
The menu shows the fl ow temperature in the circuit when a mixing valve
is used, e.g. for fl oor heating. The temperature varies with the outdoor
temperature.
The menu only applies together with a room sensor. The menu shows the
temperature in the room where the sensor is installed. Tgt (Set point value)
is the value the heat pump attempts to maintain.
The menu shows the compressor’s working temperature. The temperature
varies between 70ºC and 135ºC during operations.
The menu shows the temperature of the radiator water as it leaves the heat
pump. It varies depending on the outdoor temperature and whether the
heat pump is in hot water production mode.
The menu shows the temperature of the water that is led into the heat
pump. It varies depending on the outdoor temperature and whether the
heat pump is in hot water production mode. The heat pump stops at 48ºC
for reasons of safety.
The menu shows the temperature of the water inside the heat pump’s
condenser. It varies depending on the outdoor temperature and whether the
heat pump is in hot water production mode. The temperature drops when
defrosting. If the temperature becomes too low the defrosting alarm trips.
Temperature readings
Return radiator GT1
Off 21,3
O
Now 21,7
O
Return
Temperature readings
Out GT2
14,0
O
Return
Temperature readings
Hot water GT3
Off 47,5
O
Now 45,8
O
Return
Temperature readings
Mix valve
ß
ow GT4
Tgt 40,3
O
Now 43,0
O
Return
Temperature readings
Compressor GT6
90,0
O
Return
Temperature readings
Heat tr
ß
uid out GT8
45,0
O
Return
Temperature readings
Heat tr
ß
uid in GT9
22,0
O
Return
Temperature readings
Room GT5
Tgt 20,0
O
Now 19,5
O
Return
Temperature readings
Condenser GT10
22,0
O
Return
All menus for the temperature sensors
All the windows associated with the heat pump’s temperature sensors are
presented below. Note that you cannot make any settings in these menus,
only read the current values. Some menus are standard while others are
available only in combination with different accessories.
Basic functions (Customer level 1)