12
FOR THE USER
The control panel
All settings are made from the control panel. It also displays heat produc-
tion statistics and information about different alarms. When you have
made your settings, the control panel makes sure they are saved in the
control unit Rego 637 to carry out your wishes.
Control panel
Menu dial
Status lamps
Power switch (ON/OFF)
Buttons and lamps
Power switch (ON/OFF)
You start and stop the heat pump using the power
switch button.
Lamp on: The heat pump is on.
Lamp fl ashes: The heat pump is off.
Operating status
Lamp on: The heat pump (compressor) is
operational.
Additional heat status
Lamp on: The heat pump is using additional heat
from, e.g. an electric cassette.
Hot water status
Lamp on: The heat pump is heating water in the
cylinder.
Lamp fl ashes: The heat pump has a hot water
peak or is producing extra hot water.
Alarm status
Lamp fl ashes: A fault has occurred in the heat
pump.
Lamp on: The alarm has been acknowledged, but
the fault remains.
Heat
Heat
Pressing once gives a shortcut to the most
frequent temperature settings.
Info
Pressing once gives continuous information about
the heat pump’s and additional heat’s operating
conditions.
Menu
Press once to enter the main menu.
The main menu contains all setting menus and
temperature displays.
Info
Menu
Menu display
Menu buttons
Control panel
Rego 637 K1
040622 16:08:15 Tu
Heat Info Menu
Rego 637 K1
040622 16:08:15 Tu
Heat Info Menu