21
FOR THE USER
Extra functions
( Customer level 2)
In the section Basic functions (Customer level 1) we presented the
functions that you will probably use the most and which you will receive
the most benefi t from. However, there are numerous extra functions that
you can use to control your heat pump. This can, for example, include
activating the heat pump’s holiday function or setting the time and date.
If no settings are made on Customer level 2 (K2), the menu display will
automatically return to Customer level 1 (K1) after 30 minutes. Proceed as
follows to access the extra functions on Customer level 2:
1. Press the Heat button until Access = CUSTOMER2 is displayed.
2. Press the Menu button to open the
Main menu
From Customer level 2
you also have access to all Customer level 1 functions.
Note
You also have access to all the basic
functions on Customer level 1 from
Customer level 2.
Only the most frequently used menus in
Customer level 2 are shown in the menu
outline. All the menus cannot be pre-
sented due to space limitations. Use the
menu dial to scroll through the menus.
Press the Heat button until
Access = CUSTOMER2 is
displayed.
( Initial menu)
Extra functions - Customer level 2
The menu display is standard
on all heat pumps.
=
=
The menu display is only
shown on the heat pump in
combination with an extra
sensor or for a specifi c model of
Greenline HT Plus.
Heat curve
adjust. (break) 1.3
Page 22
Main menu
Indoor temperature
settings 1
Page 23
Mix. valve incr/decr
range 0-10 1.5
Page 23
Mix. valve fi ne-tune
range -10/+10 1.6
Page 23
Adjusting mix. valve
curve (break) 1.7
Page 23
Setting of room
sensor infl 1.11
Page 22
Setting of holiday
function 1.12
Page 22
Remote control
temperature 1.13
Page 22
Setting of summer
disconnection 1.14
Page 22
Main menu
Adjusting the hot
water settings 2
Page 24
Interval for
hot water peak 2.2
Page 24
Main menu
Timer control
accord. to clock 4
Page 24
Clock setting HP
accord. to clock 4.1
Page 24
Setting level
heat pump +/- 4.1.1
Page 25
Clock setting DHW
accord. to clock 4.3
Page 25
Main menu
Op. time readings on
HP and add. heat 7
Page 25
Heat pump in operat.
number of hours? 7.1
Page 26
Distribution HP
DHW-Rad in % 7.2
Page 26
Add. heat in operat.
number of hours? 7.3
Page 26
Distribut. add. heat
DHW-Rad in % 7.4
Page 26
Main menu
Clock, setting
time and date 10
Page 27
Main menu
Alarm logging
of all alarms 11
Page 27
Main menu
Return to
factory settings 12
Page 27
Menu outline for Extra functions (Customer level 2)
Rego 637 K2
040622 16:08:15 Tu
Heat Info Menu
Rego 637 K2
040622 16:08:15 Tu
Heat Info Menu