GB-16
INDOOR TEMP.
OUTDOOR TEMP.
COOLING
upper
limit
32˚C 43˚C
lower
limit 21˚C –10˚C
HEATING
upper limit
27˚C 24˚C
lower
limit
–
–25˚C
• The built-in protective device may prevent the unit
from operating when used out of this range.
• Condensation may form on the air outlet if the unit
operates continuously in the COOL or DRY mode
when humidity is over 80 percent.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store
settings when a power failure occurs.
After power recovery, the unit will automatically
re-start in the same settings which were active before
the power failure, except for timer settings.
If the timers were set before a power failure, they will
need to be re-set after power recovery.
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for
two to fi ve minutes after the unit is turned on to prevent
cold air from blowing out of the unit.
DE-ICING FUNCTION
• When ice forms on the heat exchanger in the outdoor
unit during the HEAT operation, an automatic de-icer
provides heat for about 5 to 10 minutes to remove
the ice. During de-icing, the inside and outside fans
stop operating.
• After de-icing is completed, the unit automatically
resumes operation in the HEAT mode.
HEATING EFFICIENCY
• The unit employs a heat pump that draws heat from
the outside air and releases it into the room. The
outside air temperature therefore greatly affects the
heating effi ciency.
• If the heating effi ciency is reduced due to low outside
temperatures, use an additional heater.
• It takes time to warm up and heat the entire room
because of the forced air circulation system.
ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE