IVM Vent-Tech SWG B Series Скачать руководство пользователя страница 10

www.internationalvalve.com

 

 

 

INSTALLATION, OPERATION AND MAINTENANCE MANUAL 

MODEL SWG, SERIES C, B, V, N 

 

International Valve Marketing, LLC

 

Page | 10

 

Last Revision Date: 09/13/2013

 

 

 

Two  side  ports  are  provided  on  each  valve.    The  upper  port  is  called  the  gauge  port  and  the 
lower port is called a pressure relief port.  After gaining a familiarity with the pipeline conditions 
and your Vent-Tech valve, these ports utilized together can serve as flushing ports to flush the 
valve without requiring disassembly and re-assembly of the valve.  Using the upper port as the 
inlet and the lower port as the outlet, a certified system maintenance mechanic can: 

 

Close the isolation valve and depressurize the valve.  

 

 

Flush a stream of water with a maximum recommended temperature of 160o F through the 
valve.  In the rare occasion where temperatures above 180

o

 F are beneficial, please contact 

IVM engineering.  

[email protected]

 

 

Continue flushing the valve until water runs clear 

 

Consult local requirements for handling of pipeline emissions. 

An example maintenance worksheet is included in the Addendum at the end of this manual 

(d)

 

Troubleshooting Air Valve Problems  

This

 section contains a table that describes possible solutions to problems that may occur when using 

your air valve. The table contains:  

• 

Symptoms 

that describe the type of problem.  

• Reasons 

for the problem 

• 

Possible solutions 

that describe what you should do to try to solve the problem.  

 

 

 

 

 

 

 

 

 

Trouble Shooting 

Symptom 

Reason 

Possible Solutions 

Leak at Large Orifice 

Debris stuck in valve 

Follow enclosed Maintenance 
Instructions 
 

Leak thru Center anti-
surge orifice 

Nozzle not sealed in Nozzle Float 

Follow enclosed Maintenance 
Instructions 
 

Leak at Sealing Flange and 
body flange 

Sealing Flange not secured 

Tighten Sealing Flange Fasteners 

Small volumes of water 
evident on top of Anti-
Surge Float or top Sealing 
Flange during start-up 

Normal operation of valve 

No solution required 

WARNING!     POTENTIAL SCALDING HAZARD!  

Using hot water at temperatures above 120

o

 F poses the risk of personal injury if proper awareness,, 

care and attention guidelines are not followed. 

Содержание Vent-Tech SWG B Series

Страница 1: ...ernationalvalve com Operation and Maintenance Manual VENT TECH MODEL SWG SERIES C B V AND N MODEL SWG SERIES C B V AND N WASTE WATER AIR RELEASE AND VACUUM RELIEF VALVES Revised 09 13 13 Vent Tech Sew...

Страница 2: ...cuum relief valve for sewage duty Vent Tech manufactured by International Valve Marketing IVM LLC was incorporated in 2009 for the express purpose of expanding and improving the technological advances...

Страница 3: ...age and file a claim with the carrier if damage is apparent Carefully unload all valves to the ground without dropping The valve should be lifted by the body the sealing flange fasteners or where appl...

Страница 4: ...up Discharge of air gas from pressurized pipeline Surge control to prevent the development of hydraulic transients during start up and pressure surges Full port high volume air intake for vacuum relie...

Страница 5: ...downtime Order parts from your local Vent Tech sales representative or directly from International Valve Marketing When ordering parts please refer to the following If the valve has a Vent Tech name...

Страница 6: ...RK V SWG08ORK N 10SWG SWG10ORK C SWG10ORK B SWG10ORK V SWG10ORK N 12SWG SWG12ORK C SWG12ORK B SWG12ORK V SWG12ORK N O Ring Repair Kit Part Numbers Valve Size Series C Series B Series V Series N 02SWG...

Страница 7: ...el SWG Series C B V N Air relief valves should be made with careful review by the system engineers Critical elements of a successful air relief valve installation are recommended below 1 Install isola...

Страница 8: ...ice Anti Surge Float 5 and check sealing O ring for damage 6 Remove Control Float 6 and Nozzle Float 7 assembly from valve body 7 The valve is now dis assembled Clean top flange anti surge float and c...

Страница 9: ...O clock 3 O clock and 9 O clock fashion by hand until all bolt nut assemblies are hand tight Tighten nuts and bolts again with a wrench Locate washers on the nut side of the flange 10 Follow standard...

Страница 10: ...runs clear Consult local requirements for handling of pipeline emissions An example maintenance worksheet is included in the Addendum at the end of this manual d Troubleshooting Air Valve Problems Th...

Страница 11: ...e float Valve body is now pressurized Buoyancy lifts control float Seats control and nozzle floats against anti surge float Valve body is now pressurized Buoyancy lifts control float Seats control and...

Страница 12: ...nistrative fees or any costs incurred in removing or reinstalling the Product to coverage for any claims submitted to Seller after expiration of the applicable warranty time period described in this W...

Страница 13: ...d nozzle plates necessary to the repair of products delivered under this warranty free of charge FOB factory for a period of ten 10 years The foregoing remedy shall constitute the sole and exclusive r...

Страница 14: ...171 3 8 16 236 201 247 210 1 8 286 243 299 254 3 8 24 259 220 271 230 1 14 259 220 270 230 7 16 14 376 320 393 334 1 1 8 7 413 351 432 367 7 16 20 400 340 418 355 1 1 8 12 390 332 408 347 Bolt Size A2...

Страница 15: ...and remnants of the sewage media However this debris and or FOG should be monitored so it does not interfere with seating of any O rings or with the movement of any of the floats Over time there will...