you can operate on the keyboard to stop the auto scan. Operation is as below: 

a.  Input 138(108) 

b.  Press PREVIEW key 

The Auto Scan can also be stopped by any operation on the joystick of the keyboard. 

 

7.7 Configure, Activate and Idle the Default Position function 

The unit has default position function. The user can configure default position for a key monitoring area according to 

actual conditions. If not operated after  2 minutes, the IR Low-speed dome camera will automatically  turn to the default 

position and monitor. 

1.  Configure the Default Position 

Move the IR Low-speed Dome Camera to a key monitoring area through controlling keyboard, adjust the zooming 

ratio  well,  then  enter  number  “164”(124)  from  the  keyboard  and  press  the  “PREVIEW”  key,  then  the  configuration  is 

successful. 

2.  Activate and idle the Default Position function 

The user can activate or idle the function of default position through the keyboard. Enter number “162”(122) and press the 

“PREVIEW” key, the function is activated. Enter number “163”(123) and press the “PREVIEW” key, the function is idled. 

 

7.8 Open and close the menu of camera module 

    The unit has a function as “configuring the parameters of the Camera Module”. Users can open and close the menu 

of  the  camera  module  by  invoking  145  and  146  “preset  positions”.  After  entering  the  menu,  users  can  configure  the 

camera module conveniently. The operation is as below: 

1. Open the menu of the camera module 

a. Input 145(95) 

b. Press PREVIEW key. 

2. Close the menu of the camera module 

a. Input 146(96) 

b. Press PREVIEW key. 

Attention: 

If the camera module doesn’t have menu function, this function with the unit is unavailable. 

 

VIII. Table for the functions of the IR Low-speed dome camera 

Notice: “PELCO-D” and “PELCO-P” protocols have no corresponding orders for part of the special functions, so we 

converted functions of some of the commonly-used orders, generally converting in the way of “invoking preset position/ 

configuring preset position”. Order converting correspondence is shown in the following table: 

Invoke “preset 

position” No. 

Keyboard operation meaning 

Invoke “preset 

position” No. 

Keyboard operation meaning 

130 

Configure left limiting position 

125 

IR  lamps  to  be  triggered  by 

photosensitive resistor (default) 

131 

Configure right limiting position 

126 

IR  lamps  to  be  triggered  by 

camera module 

Содержание IV-WP866PL

Страница 1: ...IR Low Speed Dome Camera User s Manual Please read the manual carefully before installing and using the unit...

Страница 2: ...Dome Camera 15 6 1 Configure Protocol 15 6 2 Configure Baud Rate 16 6 3 Configure Address 16 VII Basic functions of the IR Low speed Dome Camera 18 7 1 Power on and self examining of the unit 18 7 2...

Страница 3: ...s RS 485 and video signal adopt TVS class lightning damage preventing technology which can effectively prevent such pulse signal damage caused by lightning under 500W or electric surge RS 485 and vid...

Страница 4: ...ct is greatly improved With varieties of high performances the IR Low speed Dome Camera can be applied in every walk of life to monitor moving objects in large areas such as monitoring smart buildings...

Страница 5: ...io 22X Optical Focal length 3 9 85 8mm IR feature Electronic dual light filter day night Min Illumination Color 0 2LUX B W 0 05LUX S N ratio 48dB Synchronization Internal ES auto 1 50 1 10000sec BLC O...

Страница 6: ...mm IR feature Dual light filter day night auto switch switch linkage Min Illumination Color 0 12LUX B W 0 05LUX S N ratio 48dB Synchronization Internal ES auto 1 50 1 30000sec BLC On Off Switchable AG...

Страница 7: ...re Dual light filter day night auto switch switch linkage Min Illumination Color 0 3LUX B W 0 05LUX S N ratio 50dB Synchronization internal external ES auto 1 50 1 90000sec BLC On Off Switchable AGC A...

Страница 8: ...mm IR feature Dual light filter day night auto switch switch linkage Min Illumination Color 0 12LUX B W 0 05LUX S N ratio 48dB Synchronization Internal ES auto 1 50 1 30000sec BLC On Off Switchable AG...

Страница 9: ...as below A Higher brightness Since LED Array is integration of LED the brightness and the viewing distance are greatly increased B Longer lifespan due to the difference of the transparent material an...

Страница 10: ...dome camera According to actual requirement the user can arrange the preset positions into the automatic tour in the desired order then the user can use such equipment as controlling keyboard to make...

Страница 11: ...e center of the view When simultaneously observe a far object and a near one clarity for both of the images can not be guaranteed at the same time When observing objects with extreme brightness such a...

Страница 12: ...installation testing so the user can directly carry out the installation 5 Before installation please carefully read the instruction for installation in the User s Manual which is enclosed with the u...

Страница 13: ...wer cable communication cable and video cable through the bracket tube then push the installing port on the top of the outer housing into the installing hole of the bracket tighten the 3 M6 screws and...

Страница 14: ...a is shown below Cable Application Connecting Objects Remarks Power cable DC15V power supply IR Low speed dome power supply adaptor Inner positive outer negative 485 cable 485 controlling signal IR Lo...

Страница 15: ...he installing hole of the bracket tighten the 3 M6 screws and fix well Make sure the M6 screws just fit in the screw slot of the installing port of the housing D Put the power adaptor into some instal...

Страница 16: ...d is ready to receive controlling instructions c Use controlling device to control the IR Low speed Dome Camera checking whether it can perform the functions of the pan tilt and the lens of the camera...

Страница 17: ...itches from DIP 1 to DIP 8 are equivalent to a 8 bit binary figure The state ON of each bit means 1 while OFF means 0 Corresponding state of coding switches and address is shown in the table below Cor...

Страница 18: ...0101000 107 01101011 138 10001010 169 10101001 108 01101100 139 10001011 170 10101010 109 01101101 140 10001100 171 10101011 110 01101110 141 10001101 172 10101100 111 01101111 142 10001110 173 101011...

Страница 19: ...g performance of the pan tilt the electrical performance of the controlling system the controlling of the camera module After the IR Low speed Dome Camera finishes self check it stays at the original...

Страница 20: ...goes the second one Enter the second desired preset position number and press the PREVIEW key and the second preset position is successfully added More preset positions can be added in the same way C...

Страница 21: ...miting Position Operate the joystick towards left adjust the image to the desired postion then A Input 130 100 B Press PREVIEW key 2 Configure the Right Limiting Position After the Left Limiting posit...

Страница 22: ...on is idled 7 8 Open and close the menu of camera module The unit has a function as configuring the parameters of the Camera Module Users can open and close the menu of the camera module by invoking 1...

Страница 23: ...menu of the camera Module 106 Start Pan tilt 360 scanning 96 Exit menu of the camera Module 108 Stop Pan tilt auto scanning 122 Activate default position function 110 Start tour configuration 123 Idl...

Страница 24: ...ocus state Operate the IR Low speed Dome Camera or invoke any preset positions Vitreous cover dirty Clean the vitreous cover Some IR Low speed Dome Camera out of control or control delayed Power suppl...

Отзывы: