![IVDT SkidWeigh ED2-EP Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ivdt/skidweigh-ed2-ep/skidweigh-ed2-ep_installation-and-calibration-manual_2097225008.webp)
Important Note:
If you want the system to show load weight in pounds, use the known load weight in
pounds and enter that value accordingly. The same would apply if you want the system to
show load weight in kilograms. Use the known load weight in kilograms and enter that
value into the system accordingly.
Two Buttons Weighing Scale Calibration Procedure
The ED2-EP SkidWeigh system is using two buttons to calibrate the weighing scale function. The
calibration procedure for the ED2-EP SkidWeigh series is fully automatic and is done by lifting
empty and loaded forks by holding the lift control valve until the forks are automatically stopped
and the session measurements are taken
. For the best results use at least minimum calibration load test
weight of 50% to 80% of maximum lifting capacity of the electric pallet truck.
Use customer floor scale or find a known skid load weight within the operational facility.
Calibration starting point for weighing function
Lower the empty forks to the ground.
There should be no hydraulic pressure in lift hydraulic circuit.
!
- Turn vehicle power switch to on position . If the LED display does not show any number(s), turn o
n
the main power
switch located on top of the housing.
.
!
!
- LED display will show software version for the moment, as of example 30075 or 1200. After few seconds LED Mode
window will show number
8
.
System is ready to be calibrated.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
System Power On Switch