- With forks on the ground press
“M”
button to advance to Mode
“6”
and lift loaded forks just above the ground.
Within few seconds display will show the value of the known load weight.
Standard ED2-AT SkidWeigh System
Weight Calibration Function For Standard ED2-AT Series Is Done
OPTIONAL (
ED2-AT-SM
): Overload Warning Input Value Procedure
•
In order to input the overload value into the system you
must lower the loaded forks to the ground.
• The
Mode number
8
will automatically advance to the
Mode 7.
Using the
“M”
and
“Up Arrow”
keys enter the overload weight value for your application. The
Mode 7
digit remains
throughout this operation. On the last shift utilizing
“M”
key the
Mode 7
digit will turn off. The overload weight value will
be successfully stored in the system memory.
•
Note:
If the overload input value is as of the example
4850
, having only 4 digits
make sure that 5th digit is
0
.
Mode
Digit 5
Digit 4
Digit 3
Digit 2
Digit 1
7
0
4
8
5
0
ED2-AT Series SkidWeigh Systems
Weight Calibration And Overload Warning Function Is Done