Accumulative Load Weight Function

  

(ED2-AT, ED2-Print and ED2-AT-SM SkidWeigh Series) 

      

Right Button (

Red

) :

 Accumulative total  load weight 

RESET

 and

 PRINT

.

• Every time LED display shows load weight and left button

 (Black)

 is pressed, the load weight will be 

added into a weighing total counter. Display also shows the current total weight of all loads entered into the 
weighing counter.

• A quick “blink” on LED display indicates that current load weight has been added into the total weighing 

counter.

• Every time that LED indicator shows the load weight and the right button (

Red

)

 is pressed, the current load 

weight or current total weight in weighing counter memory will be reset. In the case of the system 
equipped with on-board printer, the weight ticket will be printed.

• The current load weight will be shown on LED display until next time forks are lowered to the ground.

Sample of load weight printouts

                   

                           

 

Check weighing accuracy is /- 0.1 to 1% of lift truck maximum lifting capacity

.

Overload Warning:

 Every time the pre-set overload load weight is lifted the LED display will show the load 

weight  value. All digits  will “FLASH”.  Buzzer  will  be  activated  as well if the  system  equipped with  audio 
warning. To stop LED display “FLASHING” and to turn buzzer off, lower the overloaded weight to ground.

       

Integrated Visual Data Technology Inc.   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7  

    

Содержание SkidWeigh ED2-AT Series

Страница 1: ... ED2 AT Series SkidWeigh System Lift Truck On board Check Weighing With Accumulative Load Weight Total ED2 AT Series SkidWeigh V 1 1 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 ...

Страница 2: ...ian or end user electro and hydraulic technical installer Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrical tape and shrink tubing where necessary This prod...

Страница 3: ...ressure transducer installation precautions Before installation of the pressure transducer the hydraulic lift circuit must be pressure free There are two ways to do that 1 Place the forks on the ground in their lowest position and make the hydraulic system pressure free by tilting the mast forward The chain s should be slack 2 Lift the forks and position them on the top of a supporting fixture Sta...

Страница 4: ...WHITE wire of the pressure transducer cable Pressure transducer cable Pressure transducer cable must be connected to the digital indicator seven wires single cable White Wire signal 0 to 2 5 V Black Wire signal negative Red Wire power supply to pressure transducer 11 V DC Electrical power short circuit protection All of the SkidWeigh systems are internally short circuit protected with resettable f...

Страница 5: ... The next procedure will be to calibrate the SkidWeigh weighing function Lift truck equipped with hydraulic accumulator If the standard SkidWeigh system is installed on the lift trucks equipped with hydraulic accumulators please contact us to provide you with different digital indicator having specific software algorithm to obtain load weight accuracy within 0 1 to 1 of vehicle maximum lifting cap...

Страница 6: ...o activate buttons Do not push buttons too hard Left most significant digit represents Mode of operation Other five digits represent the load weight readout Mode LED Digit Five Digits Load Weight Display MODE Digit 5 Digit 4 Digit 3 Digit 2 Digit 1 Note Every time the power is applied the software version will be shown momentarily for a brief moment When forks are lowered to ground LED display wil...

Страница 7: ...ox 5 seconds After 5 seconds the Mode display digit will change from number 8 to 0 System is ready for automatic zeroing of the scale function When LED display is showing 0 in Mode digit lift the empty forks or attachment such as longer forks clamp etc just above the ground Note Activate the lift control valve as you would do during the normal lifting operation Do not lift the empty forks slowly W...

Страница 8: ...least significant digit of your known load weight Use the M button to increment to next digit on the LED display First least significant digit 0 Second least significant digit 0 Third least significant digit 0 Forth least significant digit 4 Must enter 0 Repeat this procedure until the Mode digit display is showing number 4 Caution In our example a known load weight value of 4000 kg consist only o...

Страница 9: ...utomatically advance to the Mode 7 Using the M and Up Arrow keys enter the overload weight value for your application The Mode 7 digit remains throughout this operation On the last shift utilizing M key the Mode 7 digit will turn off The overload weight value will be successfully stored in the system memory Note If the overload input value is as of the example 4850 having only 4 digits make sure t...

Страница 10: ...s the load is lifted digital display will go blank for a moment and the load weight will be shown on the LED display Note To initiate the Weighing Cycle the LED indicator must show Mode 8 If LED display shows any other number lower the forks to the ground Always activate lift control valve lever quickly and lift the load weight just above the ground Do not attempt to lift the load slowly Accumulat...

Страница 11: ... load weight or current total weight in weighing counter memory will be reset In the case of the system equipped with on board printer the weight ticket will be printed The current load weight will be shown on LED display until next time forks are lowered to the ground Sample of load weight printouts Check weighing accuracy is within 0 1 to 1 of lift truck maximum lifting capacity Overload Warning...

Отзывы: