User’s Manual
Lift truck operator copy
Standard Weighing Procedure
(All ED2-AT Series SkidWeigh & FreightWeigh systems)
•
Insert the forks into the pallet load. Lower the forks to the ground. With no hydraulic pressure in lifting line
the
Mode LED display will show number
8
.
System is ready to weigh product on the forks.
•
Activate the lift control lever and lift the load just above the ground.
•
As soon as the load is lifted, digital display will go “blank” for a moment and the load weight will be shown
on the LED display.
Note:
To initiate the
“Weighing Cycle”
the LED indicator must show
Mode 8
. If LED display shows any
other number, lower the forks to the ground. Always activate lift control valve lever “quickly” and lift the load
weight just above the ground. Do not attempt to lift the load slowly!
Accumulative Load Weight Function
(ED2-AT, ED2-Print and ED2-AT-SM SkidWeigh Series)
Left Button (Black) :
Accumulative