3
NOTICE REGARDING POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as
required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no
termination on the load side and an LCDI attachment plug on the line side.
The LCDI power cord and plug will disconnect the power supply at the source via an electrical disconnect (circuit trip)
if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain disconnected and the unit will not work until the unit has been manually reset. This is intended
to reduce the risk of a fire in the power cord or any combustible materials that might be nearby. The cord shields are
not grounded and they must be considered a shock hazard if they are exposed. The cord shield must not be
connected to the ground wire or to any exposed metal.
WARNING:
1. DO NOT press the TEST button while the air conditioner is in operation.
2. DO NOT use the TEST and RESET buttons as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
The test and reset buttons on the LCDI plug are used to ensure the plug is functioning properly. To test the plug using
the buttons, follow these instructions:
1. Plug the power cord into the wall outlet. The LED light on the plug should light up.
2. Press the TEST button. At this point, the circuit should trip, cutting power to the air conditioner. When this occurs,
the LED light will turn off.
3. Press the RESET button to restore power to the unit. Once power has been restored properly, the LED light will
light
back
up.
If you press the TEST button, and the LED light does not turn off, or the air conditioner can still be powered on,
current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI plug in these
circumstances. Contact Ivation® Customer Care immediately for troubleshooting and repair recommendations.
Note: Your unit’s power cord may
differ from the one shown.
RESET
TEST
LED LIGHT