Table 3, faults when connected to a 24 V DC power supply
Signalling
Problem
Cause
Solution
LEDs on anti-static
bar do not light up
No high voltage at
emitters
No supply voltage
Switch on supply
voltage
Wiring fault
Locate fault and
remedy, see 5.6
LEDs on anti-static
bar flashing green
No high voltage at
emitters
No remote on/off signal
Connect/activate
remote on/off
Wiring fault
Locate fault and
remedy, see 5.6.3
LEDs on anti-static
bar light up red
Anti-static bar
overloaded
Anti-static bar fouled
Clean anti-static bar
Anti-static bar fitted
too close to conductive
machine parts
Move anti-static bar
LEDs on anti-static
bar light up green
No/poor ionisation,
despite high voltage
at the emitters
Anti-static bar fouled
Clean anti-static bar
Emitters are damaged
Replace the anti-static
bar
Anti-static bar incorrectly
positioned
Reposition the anti-
static bar, see 5.2
Emitters are covered
Remove the cover
LEDs on anti-static
bar flashing red (1
Hz)
High voltage at the
emitters, no HV OK
signal
HV OK overloaded
Load HV OK differently
Wiring fault
Locate fault and
remedy, see 5.6.3
LED on anti-static bar
flashes red (5 Hz)
No communication
with IQ Easy
platform
During power up the
possibility of
communication is
checked
Ignore during power up