IQ POWER BPS-C POWER SUPPLY
Figure 2. IQ Power BPS-C Dimensions
Electrical Connection
1.
Ground BPS-C
by connecting ground lead between ground terminal on flange
of the power supply and a good electrical machine ground.
2.
Ground Conveyostat
by connecting ground lead between ground terminal on
Conveyostat and ground stud on power supply or a good electrical machine
ground.
3.
Connect BPS-C to Conveyostat
using an IQ Power Extension Cable. The
Conveyostat must be equipped with a two-prong HV connector assembly. The
connector assembly at the Conveyostat plugs into the receptacle end of the
HV extension cable. Secure connection with (2) captive screws on connector,
DO NOT over-tighten screws. HV extension cables may be chained together
to a maximum of 300 feet {915 meters] per BPS-C. The plug-end of HV
extension cable plugs into HV1 or HV2 on the BPS-C. Secure connection
with (2) captive screws on plug, DO NOT over-tighten screws. See BPS-C and
Conveyostat connection diagrams.
CAUTION – Electrical Shock Hazard
Do not connect static neutralizing bar with power supply energized.
Disconnect input power or switch power off before connecting static bar.
ATTENTION – Risque de choc électrique
Ne branchez pas la barre de neutralisation statique avec alimentation sous
tension. Couper l’alimentation ou coupez le courant avant de connecter la
barre statique.
NOTE
– Failure to fully seat the high voltage connectors into the power
supply connectors may result in permanent damage to the bar, cable, or
power supply.