CONVEYOSTAT
IN-LINE IONIZER
5100577 Rev J
Figure 3
AC Line Power (Low Voltage) Connections
CAUTION
– Do not apply line voltage to the Power Unit until all grounds and
high voltage connections have been completed and the Conveyostat has been
installed.
1. Connection should be made only to a 3-wire 120V, 60 Hz or 230V, 60 Hz AC source.
2. For rigid cable connection to the power unit: the use of local code approved solid
3-conductor cable through ½” size conduit with approved fittings is recommended
(not supplied). On installations subject to Canadian Standards Approval: the use of
conduit is required.
3. For flexible connection to power unit: the use of local code approved 3-conductor line
cord is recommended (not supplied). Secure line cord to power unit with an approved
cable clamp.
4. Connect the power source to the black and white leads using proper size wire nuts.
Connect the grounded conductor to the ground post.
NOTE
– If the Conveyostat is to be used on machinery, it is recommended that
the power unit’s input wiring be connected to the machine’s RUN button. This
will enable the power unit to be turned ON and OFF with the machine.