PROBLEM
CAUSE
SOLUTION
Power indicator
NOT illuminated
Power not on at power supply
Turn on Power switch on end of power supply case
Poor electrical connections
Check input power connections, both 24 VDC and
line voltage; check modular cable if used with a
Control Station
Defective AC adapter
Replace AC adapter
Blown device fuse in Control Station
Try another modular connector on Control Station
Clean Bar indicator
illuminated
Process material fouling static bar ion emitters
Remove process material from static bar
Dirt build-up on ion emitters or conductive
contamination on face of bar
Clean ion emitters and static bar
See Maintenance section for details
Bar ON indicator
NOT illuminated
No static bar connected
Install static bar and connect to power supply
High voltage connector is not connected
Turn off power, reconnect high voltage cable and
secure plug with captive screws
High voltage connector missing bar type sense
pin at BPS-C
Replace high voltage connector plug at BPS-C
Bar power off at Control Station
Turn bar power on through device page on Control
Station
Fault indicator
illuminated
Static bar shorted to grounded metal
Clear debris shorting static bar to grounded metal
Damage to high voltage connector
Replace high voltage connector
Damage to high voltage cable
Replace defective cable
High voltage module inside power supply faulty
Replace high voltage module
Locked indicator
NOT illuminated
Power supply operating stand-alone
Locked indicator only illuminates if Control Station
connected
Poor electrical connection
Check connections of modular cable at power supply
and Control Station