IQ POWER MPS POWER SUPPLY
5201279 Rev A
Web/Bar Width
- A user entered dimension, the width of the web that the static bar
is being used with. This value is used in charge estimation.
Web Speed Mode
- Displayed with the source on control station. A user entered
value, “Device” if stored in the MPS, “Global” if stored in the Control Station.
Ion Current
- The ionization level in terms of microamps for both positive and
negative ionization.
Up Time
- The amount of time elapsed since the device was turned on.
Device Address
- The Power Supply Number (address / device number) assigned
to the MPS. The address may be edited, but duplicate address numbers are not
permitted. The exception to this rule is static sensor bars. If a static sensor bar is
given the same address number as an MPS its data will appear as a tab under the
MPS and it will automatically become paired with that MPS for CLFB operation.
Device Version
- The firmware revision in the device.
Device Locator Utility
- Causes the indicator lights on the device to flicker for a
brief time to aid in verifying location of a given device.
IQ MPS Calibration
- A time stamp indicating the last time the power supply was
calibrated.
Alarm Test Utility
- Causes a fault output to aid in checking /troubleshooting fault
sensing connections.