3
CHARGEMASTER VCM
5201247 Rev. C
3. SPECIFICATIONS
Output Voltage
VCM30: 0-30 kV
, VCM60: 0-60 kV
Output Current
VCM30: 0-5.0 mA, VCM60: 0-2.5 mA
Output Power
150W max
AC Input Voltage
85-264V
AC Input Frequency
47-63 Hz
Fuse (rear-panel)
3.15 AT
Output Connections
4 output ports (Simco-Ion SLCC type)
Remote Control Connection
25-pin D-Sub connector
Cooling
Convection
Polarity
N = Negative, P = Positive
Short-Circuit Protection
Output electronically protected at max output current
Input Power Connection
IEC-320 AC receptacle (North American 115 and 230 line cords are
provided with each VCM unit)
Resolution of Display
0.2 kV, 0.05 mA
Voltage Stabilization
2% of maximum output voltage with input voltage between 85 and
264V
Load Stabilization
2% of maximum output voltage at load fluctuation between 0 and
maximum rated load
Ripple, Peak-Peak
10% of maximum output voltage at maximum load
Remote On/Off
0V = OFF, 12V = ON (typical)
Control Voltage Range:
10 V
, 10 mA min
30 V
, 25 mA max
Internal Power Supply
12 V
(±20%), 20 mA (U
ripple
= 0.5V
tt
max) for remote on/off and
external overload signaling, if necessary
Remote Programming
0-5V, 0-10V, 0-20 mA or 4-20 mA
Ambient Temperature
32-131°F (0-55°C)
Operating Environment
Vibration-free installation
Remote Control Functions
– Switching high voltage on/off
– Output voltage & current control via standard industry control signals
– Output voltage & current monitoring
– Overload indication monitoring
– Easy to configure via D-Sub connector