Installation and Operating Instructions
05)
This ice maker should be installed in accordance with applicable national, state, and local
regulations.
06)
The machine must be installed “indoors” and should not be located next to or near high heat
producing equipment or where air inflow is limited.
07)
Electrical Connections-Check that the voltage is the same as on the nameplate before
connecting the unit. Make sure the ice maker is connected to its own circuit and individually fused.
Install a proper ground wire to the machine.
08)
Water Connection-Water supply should be a minimum of 10 psi. (0.7 bar) and a maximun of 85
psi. (6 bar). Do not connect the machine to a hot water supply.
SPIKA NG & MODULAR SERIES
Before Installation
01)
Visually inspect the exterior of the shipping container,
and report to the freight carrier; any severe damage, after
inspection, remove all packing material.
02)
Remove all internal support packing on the shields,
through the door (under-counter and self-contained models)
and removing the front panel (modular models) and removing
the front panel (modular models). Check that the ice curtain
hangs freely.
03)
Place the legs into the 4-corners at the bottom of the
machine (only under-counter and self-contained models) and
level the icemaker by adjusting them properly. (See Fig.1)
04)
Complete ITV’s warranty card and submit via fax, mail or
e-mail to
ITV’s office.
Fig.1
Leveler
4’’ (10cm)
Plug
Socket
Tap
Water Inlet
Bin Drain
6’’ (15cm)
Plug
Socket
Tap
Water Inlet
Bin Drain
Water Condenser Drain
(Water cooled units)
Fig.2
QUICK SET UP GUIDE SPIKA