Maintenance and Cleaning Procedures
CAUTION: Instruct the user about maintenance, informing that maintenance and cleaning operation as well
as damages due to the lack of such operations are not included in the warranty.
If a good maintenance is performed, the machine will continue producing a good quality of ice and will be
free of damages.
Maintenance and cleaning intervals will depend on the conditions of the site and water quality.
CAUTION:
The ice machine’s water system should be cleaned and sanitized at least twice a year.
On dusty environments, it might be necessary to clean the condenser on a monthly basis.
WARNING: Wear rubber gloves and safety goggles when handling Ice Machine Cleaner or Sanitizer.
WARNING: Unit should always be disconnected during maintenance/cleaning procedures.
Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine is cleaned and
sanitized.
FRONT GRID REMOVAL
To access condensing unit remove front grid by pressing the two clips placed at right side.
CLEANING THE CONDENSER
Air Condenser
1) Disconnect machine.
2) Close water faucet.
3) Clean condenser using a vacuum cleaner, brush or low pressure air.
Water Condenser
1) Disconnect machine.
2) Close water faucet.
3) Disconnect water entry/exit from condenser.
4) Prepare a solution of Scale-Kleen in distilled water
according to the manufacturer’s instructions.
5) Distribute solution through condenser. (Solution is more effective at 35°-40°C).
WARNING! DO NOT USE HYDROCHLORIC ACID
Evaporator / Water Deposit
1) Switch off the machine.
2) Remove overflow pipe to empty water reservoir.
3) Prepare a solution of an appropriate product for the cleaning of ice machines (lime). Do not use hydrochloric acid. We
recommend the use of Scale-Kleen (Everpure) prepared according to the manufacturer
’s instructions.
4) Fill water reservoir with the previous prepared solution.
5) Press the switch on the Panel control board and then turn
on the machine. Keep the pressure on the PCB’s switch
during few seconds until water pump starts running. Let the water pump remains working and distributing the cleaning
solution through the water circuit and after 30 min. the machine will stop automatically. Then, to power off the
machine.