IF YOU ARE NOT FAMILIAR WITH APPLICABLE
ELECTRICAL STANDARDS, HAVE THE UNIT INSTALLED BY A
QUALIFIED ELECTRICIAN.
Suggested wiring information is given as a reference. For proper
information, please reference ABYC E-11, AC and DC Electrical
Systems on Boats guidelines.
Model No
Voltage
Max Amp
Draw
Open Flow
GPM (LPM)
Switch Max PSI
(bar)
52600-0092
12 V
35
7.0 (26.5)
60 (4.1)
52600-0094
24 V
20
7.0 (26.5)
60 (4.1)
52600-0292
12 V
30
7.0 (26.5)
40 (2.7)
52600-0294
24 V
15
7.0 (26.5)
40 (2.7)
Motor case could get hot during extended
operation. Prolonged contact with skin may cause a burn.
Install a Pumpgard
TM
strainer in an accessible
location (for inspection and cleaning) between the tank and
pump inlet in order to protect valves from debris.
Operation
• Fill water tank
• Open all faucets
• Turn pump switch “ON”
• When water is free of air, turn all faucets off beginning with
the faucet closest to the pump (Figure 6)
Important:
Do not operate the pump more than 15 minutes
continuously.
!
Red (+)
+
12V DC Battery
7 Inches Max
Main
35 AMP
Main Breaker
Ring Terminals 5/16" Eye
Butt Splice
Com Bus
Battery
Switch
–
Black (–)
Panel
Switch
Helm
Console
Figure 5.
Figure 6.
Initial Start Up
Demand Off
Demand On
Fire hazard. Wiring must comply with
applicable electrical standards and include
a properly sized fuse or circuit breaker.
Improper wiring can cause a fire resulting in
injury or death.
WARNING
CAUTION
CAUTION
CAUTION