Mechanical seal with piping - for assembly instructions refer to
4.3.5 Mechanical seal options on
.
•
Coupling assembly, spacer or non-spacer type
Refer to the Certified Pump Outline Drawing for the location of the anchor-bolt holes.
1.
Clean the barrel flange and the bottom of the discharge head base.
2.
Attach shackles to the discharge head lifting lugs or thread two swivel hoist rings through the bolt
holes in the mounting flange.
3.
Hoist the unit into position over the foundation.
Make sure that the shackles, swivel hoist rings, and sling are rated to handle in excess of the pump
weight. See the outline drawing.
4.
Carefully guide the unit so that it does not strike the sides of the sub-base or foundation.
5.
Lower the unit until the discharge-head flange engages and rests firmly on the barrel flange , then
secure it with the capscrews provided.
4.3 Installing a disassembled pump
4.3.1 Installing the bowl assembly
WARNING:
Avoid working under suspended loads. If necessary to do so, follow the more stringent of local,
state or federal safety regulations.
CAUTION:
Refer to
2.3.1 Lifting methods on page 11
NOTICE:
Bowl Assembly shall be done only by ITT Goulds Pumps authorized service centers.
4.3.2 Column installation
4.3.2.1 Installing the column
VICR pumps are normally very short, therefore after bowl assembly is complete, rig, lift and place it in
horizontal position supporting at the column adaptor and suction bell or transition-stage bowl.
NOTICE:
Never rest and support the bowl assembly weight on the tie rods.
Use Molykote Dow-Corning anti-galling compound or an equivalent for all galling material such
as 316 stainless steel.
The bearing retainer is integral with the column. The top flange of the column has a male register and the
bottom flange of the column has a female register.
1.
Before starting the shafts installation, check the headshaft and lineshaft for straightness.
The average TIR should be less than 0.013 mm | 0.0005 in. per 0.305 m | foot and not exceed
0.127 mm | 0.005 in. for every 3 m | 10 ft.
2.
Apply a thin film of oil to the lineshaft.
3.
Table 5: Lineshaft coupling on page 29
.
4.3 Installing a disassembled pump
28
Model VICR Installation, Operation, and Maintenance Manual