The baseplate will rest on top of the foundation on the jackscrews provided on the baseplate.
2.
Adjust the leveling jackscrews, located adjacent to the foundation bolt holes, until the baseplate
rests 25 to 50 mm | 1 to 2 in. above the foundation in order to allow for adequate grouting.
This provides even support for the baseplate after grouting.
3.
Level the baseplate to within 0.167 mm/m | 0.002 in./ft. of the length or width of the baseplate by
adjusting the jackscrews.
•
The maximum total variation from one end or side of the baseplate to the other is 0.38 mm |
0.015 in.
•
Use the equipment mounting surfaces in order to establish the level.
4.
Use a non-bonding (anti-seize) compound such as paste wax to coat the portions of the jackscrews
that will contact the grout.
This facilitates removal of the screws after grouting.
NOTICE:
Do not use oils or liquid wax.
5.
Thread the nuts onto the foundation bolts and hand-tighten.
4.3 Install the pump, driver, and coupling
1.
Mount and fasten the pump on the baseplate. Use applicable bolts.
2.
Mount the driver on the baseplate. Use applicable bolts and hand tighten.
3.
Install the coupling.
See the installation instructions from the coupling manufacturer.
4.4 Pump-to-driver alignment
Precautions
WARNING:
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installa-
tion or maintenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
Alignment methods
Three common alignment methods are used:
•
Dial indicator
•
Reverse dial indicator
•
Laser
Follow the instructions from the equipment manufacturer when you use the reverse dial indicator or laser
methods. Detailed instructions for using the dial indicator method are contained in this chapter.
4.3 Install the pump, driver, and coupling
3640 i-FRAME API Type BB2 2-Stage / ISO 13709 2nd Ed. API 11th Ed. Installation, Operation, and Maintenance Man-
ual
23