a) Apply Lucas Heavy Duty Oil Stabilizer, or equivalent lubricant to the lower half of the sleeve
bearing (117). Place the lower half of the sleeve bearing (117) on the shaft (122) and slide it
around the shaft into the lower bearing housing. One may need to use the adjusters to lift the
frame first. Install the dowel pins in the pre-drilled dowel pin holes between the housing flange
and the head-bearing flange.
b) Tighten the nuts (427J) on the bearing housing to the head studs (371T).
c)
Apply Lucas Heavy Duty Oil Stabilizer, or equivalent lubricant to the upper half of the sleeve
bearing (117). Place the upper half of the sleeve bearing (117) on the shaft (122).
d) Install the two socket head cap screws that hold the upper and lower halves of the sleeve bear-
ing (117) together.
8.
Install the outboard labyrinth seal (332A).
9.
Install the upper half of the bearing housing (134). Prior to installing the upper half, apply a thin coat
of Permatex® Aviation Form-A-Gasket® (or equivalent) to the lower half bearing housing to prevent
possible oil seepage.
10. Install the two taper pins to line up the upper and lower halves of the bearing housing (134).
11. Install the hex cap screws that connect the upper and lower halves of the bearing housing (134).
6.6.9 Attach the i-ALERT
®
2 Equipment Health Monitor to the pump
Tools required:
•
5/32 inch hex wrench
1.
Attach the condition monitor (761B) to the bearing frame (134, 134A) using the hex-head screw
(372T) provided.
134
761B
372T
Figure 91: Attaching the condition monitor to bearing the frame
2.
Tighten the hex-head screw to 8 Nm | 6 ft-lbs.
More detailed information is available on:
http://www.ittproservices.com/aftermarket-products/monitoring/i-alert2/i-ALERT2.com
6.6.10 Post-assembly checks
Perform these checks after you assemble the pump, then continue with pump startup:
•
Rotate the shaft by hand in order to make sure that it rotates easily and smoothly and that there is
no rubbing.
6.6 Reassembly
110 3640 i-FRAME API Type BB2 2-Stage / ISO 13709 2nd Ed. API 11th Ed. Installation, Operation, and Maintenance Man-