WARNUNG:
Service temperature in an ATEX classified environment is limited to the area classification
specified on the ATEX tag affixed to the pump (reference Fastener Size and Recommen-
ded Torque Values in
3.5 3996 Shaft Alignment Procedure on page 22
for ATEX classifica-
tions).
Also, for pumpage temperatures above 200° F | 93°C the cold (ambient) setting must be inc-
reased per table below. This is necessary to prevent the impeller from contacting the casing
due to differential expansion from the higher operating temperatures.
Tabellennummer 4: Impeller Clearances - Cold Temperature Clearances for Various Service
Temperatures
Service Temperature
ST
MT
inches
mm
inches
mm
From -20 to 150°F (-29 to
66°C)
0.005
0.13
0.008
0.20
Up to 175°F (79°C)
0.005
0.13
0.008
0.20
Up to 200°F (93°C)
0.005
0.13
0.008
0.20
Up to 250°F (121°C)
0.006
0.16
0.009
0.23
Up to 300°F (149°C)
0.007
0.19
0.010
0.26
Up to 350°F (177°C)
0.009
0.22
0.012
0.29
Up to 400°F (204°C)
0.010
0.25
0.013
0.32
Up to 450°F (232°C)
0.011
0.28
0.014
0.35
Up to 500°F (260°C)
0.012
0.30
0.015
0.38
7.
Couple Pump and Driver
WARNUNG:
Lock out driver power to prevent accidental rotation and physical injury.
1.
Discharge isolation valve
2.
Check valve
3.
Suction isolation valve
Abbildungsnummer 9:
WARNUNG:
The coupling used in an ATEX classified environment must be properly certified.
1.
Install and lubricate coupling per manufacturer's instructions.
4.1 Preparation for Startup