The downstream pressure will change as the flow
changes. As the flow increases, the delivery pressure will
decrease. See the GFH20 series representative flow
performance graphs for this product.
NOTE:
The outlet set pressure will change as the inlet
pressure changes.
CAUTION:
The internal filter can retain moisture from wet
air. If this product is used in a sufficiently cold (potentially
freezing) environment, a wet filter can result in restricted or
blocked flow.
TYPICAL AIR FLOW PERFORMANCE
TROUBLESHOOTING GUIDE
Symptom
: External leakage
Potential Cause
: Diaphragm to body joint seal
leakage.
Repair:
Disassemble. Inspect regulator body where
diaphragm seals. Replace diaphragm.
Potential Cause
: Bowl to body joint leakage.
Repair:
Disassemble. Inspect regulator body where
bowl o-ring contacts. Inspect bowl where o-ring
contacts. Replace o-ring.
Potential Cause
: Draincock leakage.
Repair:
Tighten draincock by turning handle
clockwise.
Symptom
: Outlet pressure cannot be adjusted to
maximum control range.
Potential Causes:
1. Control knob positive stop adjustment.
2. Flow induced droop.
Repair:
1. Adjust positive stop of control knob.
2. See NOTE in above OPERATION IN SERVICE
instructions and flow curves for explanation – a
higher range regulator may be required.
FLOW CHARACTERISTICS
0
10
20
30
40
50
60
70
0
5
10
15
20
25
FLOW (SCFM)
OU
TLE
T (
P
S
I)