GENERAL PRODUCT OVERVIEW 
 

The HP400 Regulator is a hand operated, self-contained, 
spring loaded pressure reducing regulator. This unit offers the 
safety and reliable service of a piston sensed regulator. 
 
The model HP400 has non-venting piston sensor and a 
captured bonnet feature. An adjustable stop to limit the 
maximum output pressure is standard.

 

 
MATERIALS OF CONSTRUCTIONS 
 

The HP400 will operate with any fluid (liquid or gas) compatible 
with the materials of construction. To identify the materials of 
construction refer to the Control Engineering Data contained 
on page 3. 
 
Body Brass 
Bonnet Brass 
Main Valve Seat 

Kel-F (Vespel Optional) 

Sensor and Trim 

300 Series Stainless Steel 

Seals 

Teflon / Viton (Buna-N Optional) 

 
REGULATOR CLEANING 
 

The HP400 Series High Pressure Regulators are cleaned to 
ITT Conoflow Specification ES8A 01 294. 

 
OXYGEN SERVICE 
 

Specification of materials in regulators used for oxygen service 
is the USER’S RESPONSIBILITY. Cleaning for oxygen service 
(per ES8A 01 297) to 3500 PSIG (24.20 MPa) is supplied by 
ITT Conoflow at no additional cost. For special cleaning 
requirements, the customer must supply specifications for the 
desired level of cleaning. Cost will be advised prior to 
performing the cleaning operation.

  

 

CAUTION:

  Maximum Supply Pressure 3500 PSI (24.20 MPa) 

Maximum supply pressure can be derated based on 
connection and internal material selections.  See notes in CED 
code (page 3).

 

 

 
An internal filter screen is provided in the inlet (“IN”) port only 
to stop random contamination resulting from installation. An 
auxiliary filter is recommended for all but the cleanest fluid. 
Gaseous fluid must be free of excessive moisture to prevent 
internal icing or condensation during operation.    

 
OUTLET PRESSURE RANGES 
 

    OPTION CODE 

RANGE 

“J” 

20–2500 PSIG (0.14 -17.25 MPa) 

 
PORTING CONFIGURATIONS 
 

There are four (4) 1/4” NPTF connections on the HP400. The 
supply connection port is labeled “IN” and the supply gauge 
port is labeled “HI.” The outlet port is labeled “OUT” and the 
outlet gauge port is labeled “LOW.” Care should be exercised 
when installing the high pressure line to assure it is connected 
to the inlet (“IN”) port, otherwise the regulator will not function 
properly.

 

 
Teflon thread tape is the preferred thread sealant when the 
regulator is installed.  

 

INSTALLATION 

 

The HP400 can be line or panel mounted. For line mounted 
applications refer to porting configurations for proper 
orientation of ports. 
 

Panel Mounting:  

1. Remove handwheel, knob, or “T” bar handle and insert the 
regulator from the rear of the panel. 
2. Projection of regulator through the panel may be controlled 
by adjustment of panel mounting nuts 
3. Replace the handwheel, knob, or “T” handle. 
4. Connect inlet, outlet and gauge ports as applicable. 
 

PRINCIPLE OF OPERATION 
 

Turning the control knob clockwise will increase the force on 
the range spring and, in turn, the outlet set pressure. 
Conversely, turning the control knob counterclockwise will 
decrease the force on the range spring and decrease the outlet 

WARNING 

Conoflow’s products are designed and 
manufactured using materials and workmanship 
required to meet all applicable standards.  The use 
of these products should be confined to services 
specified and/or recommended in the Conoflow 
catalogs, instructions, or by Conoflow application 
engineers. 
 
To avoid personal injury or equipment damage 
resulting from misuse or misapplication of a 
product, it is necessary to select the proper 
materials of construction and pressure-
temperature ratings which are consistent with 
performance requirements.

 

Содержание Conoflow HP400

Страница 1: ... code page 3 An internal filter screen is provided in the inlet IN port only to stop random contamination resulting from installation An auxiliary filter is recommended for all but the cleanest fluid Gaseous fluid must be free of excessive moisture to prevent internal icing or condensation during operation OUTLET PRESSURE RANGES OPTION CODE RANGE J 20 2500 PSIG 0 14 17 25 MPa PORTING CONFIGURATION...

Страница 2: ...m bore Other tools and maintenance aids include a vise tweezers clean lint free cloth swabs and a torque wrench CAUTION MAINTENANCE It is recommended that maintenance be performed by a person experienced in the operation and repair of high pressure regulators Maintenance of this unit is best performed by gripping a protruding end of a pipe fitting installed into the regulator body WARNING Bleed Sy...

Страница 3: ... in detail the full scope of the product line In addition to the materials of construction diaphragm and elastomer selection it also provides all necessary data regarding adjustment option and range selections Control Engineering Data also provides a means of communicating by way of a code number which is fully descriptive in product selection All catalog numbers received must contain fifteen 15 c...

Страница 4: ...REGULATIONS EAR THIS INFORMATION SHALL NOT BE PROVIDED TO NON US PERSONS OR TRANSFERRED BY ANY MEANS TO ANY LOCATION OUTSIDE THE UNITED STATES CONTRARY TO THE REQUIREMENTS OF THE EAR CONNECTION IDENTIFICATION AND TYPICAL GEOMETRY FIGURE 1 HP400 REGULATOR SECTIONED VIEW FIGURE 2 HP400 REGULATOR EXPLODED VIEW ...

Страница 5: ... EAR THIS INFORMATION SHALL NOT BE PROVIDED TO NON US PERSONS OR TRANSFERRED BY ANY MEANS TO ANY LOCATION OUTSIDE THE UNITED STATES CONTRARY TO THE REQUIREMENTS OF THE EAR FIGURE 3 STANDARD HANDKNOB DIMENSIONAL DRAWING FIGURE 4 OPTIONAL WRENCHKNOB DIMENSIONAL DRAWING FIGURE 5 OPTIONAL T BAR HANDLE DIMENSIONAL DRAWING ...

Страница 6: ...E The main valve seat needs replacement follow maintenance procedure and regulator assembly PROBLEM Continuous leakage through the bonnet with the outlet pressure on the regulator POSSIBLE CAUSE Sensor O ring is worn leaking and needs to be replaced PROBLEM Regulated pressure drops off sharply when the flow is within the regulator s capabilities POSSIBLE CAUSE Clogged inlet screen Remove the old f...

Отзывы: