6.6 Signals
A two-tone LED (red / green) is installed to signal operating
and error statuses.
Labeling on terminal box:
Function LED
Message
Message
Operation
Malfunction
Pump OFF
off
off
off
Pump running in area
A
lit green
on
off
Pump running in area
B
blinking green
on
off
irregularly**
Pump running in area
C
blinking green
on
off
regularly*
Malfunction electronics
blinking red
off
on
regularly*
Minimum speed
blinking green/red
on off
Pump blocked
lit red
off
on
* = blinking regularly
1 s on / 1 s off
** = blinking irregularly
1.5 s on / 0.5 s off / 0.5 on / 0.5 off
6.7 Acknowledging malfunction
Switch off the power. Wait until the red LED goes off –
switch on again.
6.8 Bus modules
The pump can be equipped with a LON bus module.
See the special instructions.
Lit, blinking
green
Lit, blinking
red
Blinking
green/red
alternately