8. MAINTENANCE

   

.

.

.

The heat pump water heater is highly automatic equipment, which is checked periodically over its  

unit state in application. If the unit can be maintained effectively for a long time, the operation reliability

 and lifespan of the unit will be greatly enhanced.

1 The water filter installed outside the unit should be cleaned periodically to ensure a clean water supply

     in  the system in case  the unit may be damaged due to the blocked dirty water filter.

2 In using and maintaining this unit, the customer should pay attention to this point: all the safety 

    protection  equipment in the unit has been set properly before leaving the factory, therefore, it is for

    -bidden to adjust   them without permission.

3 Check frequently whether the power supply and electrical system connection of the unit are firm and 

    whether the electrical components operate abnormally. If there is, repair or replace in time.

4 Check frequently whether water supply of the system, water tank safety valve, liquid level controller,  

    and air discharge  equipment operate normally in case air should enter the system to lead to decreased  

    water cycle so as to influence the  heating ability of the unit and reliability of unit operation.

5 Check whether water pump and water pipe valves can operate normally, and whether there is any leak

   -age in water pipeline  and water pipe connections.

6 The surrounding of the unit should be kept clean with good ventilation. Clean regularly (1-2 months)  

     the air side heat  exchanger to maintain a good heat exchange effect.

7 Check frequently the operation state of each part of the unit. Check whether there is oil dirt in unit 

    pipeline connection and  air inhale valve to ensure there is no leakage of the unit refrigerant.

8 Do not pile any other object around the unit in case the air exhale should be blocked. The surrounding  

    of the unit should be  kept dry and clean with good ventilation.

9 If the machine will be stopped for a long time, discharge the water in unit pipeline, cut off power supply, 

   cover with  protection shield, and check the system comprehensively before starting the unit to operate 

    again.

10 If there is anything wrong with the unit and the customer can not solve it, make a phone call to local

     special service  department of our company so that we could send professional staff to fix it in time.

11 For cleaning of mainframe condenser, we suggest that 50

-60

 hot phosphate liquid with a density 

     of 15% can be used to clean it. Start the mainframe-equipped cycle water pump to clean for three hours  

     and then clean with running water 3 times.  (In pipeline installation, it is suggested to reserve a tee 

     connection and block one of the connection with silk block) so as to  connect pipes in cleaning. It is  

    forbidden to use corrosive detergent to clean the condenser.

12 Furring should be removed from the water tank after using for a period of time (usually two months 

     depending on water  quality in local area). 

17

Содержание ITS-17VD

Страница 1: ...HEAT PUMP WATER HEATER Installation Instruction Manual ...

Страница 2: ...tion 4 6 Normal operation 5 Operation 5 1 Controller illustration 5 2 Selecting mode 5 3 Checking current parameters 5 4 Parameter overview Table 1 5 5 Parameter overview Table 2 5 6 Setting parameter 5 7 Setting time 5 8 Setting TIMER ON OFF 5 9 Cancellation of TIMER ON OFF 6 Failure code overview 7 Wiring diagram 8 Maintenance 1 2 3 4 5 6 6 7 7 7 8 8 9 9 10 11 12 12 12 12 13 14 15 16 17 ...

Страница 3: ......

Страница 4: ...1 1 PRODUCTION INTRODUCTION ...

Страница 5: ... the condenser into low temperature liquid to discharge a lot of heat which is absorbed by water to increase its temperature Then when the high pressure and low temperature liquid throttles and reduces its pressure in expansion valve due to the fan in the evaporator it absorbs energy from the surrounding air to evaporate into low pressure gas and then is pumped into the compressor to be compressed...

Страница 6: ...70 5 8 101 55 60 G 1 2 1 1 25 850 52 960 360 550 980 380 600 48 55 PowerSupply InputPower RunningCurrent HotWaterProducedVolume Thermostat FactorySetting Maximumwatertemp WaterConnections CompressorQuantity FanMotorQuantity FanMotorInput FanSpeed Noise Rated Heating Capacity Code Net Dimension Packing Dimension Weight NetWeight GrossWeight L W H L W H ITS 17VD 17000 58000 3600 17 2 290 55 60 G 1 1...

Страница 7: ... 5mm 13AWG 2 4 0mm 11AWG ITS 17VD ITS 24 5VD3 2 4 0mm 11AWG Code Specs 2 Installation 4 INSTALLATION A C D B G H F E B SERIES B C D E F G H ITS 4 7HDP A 280 360 935 940 55 155 520 550 Model Size Unit mm 4 1 Dimensions ...

Страница 8: ...5 A SERIES D H G F E D G E H F Unit mm ITS 17VD ITS 24 5VD3 960 960 660 660 190 190 660 660 60 60 Model Size ...

Страница 9: ...foundation or bracket should be strong enough for stable operation Make sure the unit keeps straight up without any inclination after installation Do not install the mainframe in place where there is pollution corrosive gas or accumulation of dirt or fallen leaves Avoid to install heat pump close to inflammable and explosive places Make sure to observe the distance from hindrance shown by arrows i...

Страница 10: ...ve heat pump running for 3 days for the pre operation The water leak pipe or water overflow pipe should be installed near the drainage channel or vent to facilitate water discharge Water leak valve should be installed in the water leak pipe Before the electromotive electromagnetic valve in system pipeline a check valve should be installed for future check The customer s water pressure should be lo...

Страница 11: ... already connected If connection fails in 10 seconds please check connections of communication cable or replace anther controller Under standby status controller displays time and running mode Under running status controller displays time water temperature in the tank and running mode Running status Actual tank water temp 5 OPERATION ...

Страница 12: ...ther modes are in valid 5 3 Checking current parameter Under standby status or running status press or controller will display from Parameter 0 to Parameter 13 in turn with current value See more in table on next page In about 5 seconds display will return to standby or running status interface ...

Страница 13: ...lve control manual automatic Different working mode of water pump Reserved Target superheat setting Manual control of EE valve Inlet water temperature Discharge gas temperature System coil temperature Return gas temperature Ambient temperature Reserved Actual steps number of step motor in EE valve 1 30 10 60 30 90Min 0 30 2 30 1 12Min 1 2 0 1 0 1 0 1 0 1 F F 0 50 9 90 9 90 9 90 9 90 9 90 9 90 0 50...

Страница 14: ...nsion valve control manual automatic Reserved Winter anti freeze protection Target superheat Manual control of EE valve Inlet water temperature Outlet water temperature System coil temperature Return gas temperature Ambient temperature Water temperature in the tank Actual steps number of step motor in EE valve 1 30 10 60 30 90Min 0 30 2 30 1 12Min 1 2 0 1 0 1 0 1 0 1 F F 0 50 9 90 9 90 9 90 9 90 9...

Страница 15: ...tting TIMER ON OFF Press to activate timer setting for ON 00 00 and ON icon will be flashing together Press again controller displays with flashing hour and ON icon only move or to fix the hour on the timer to start on the unit Operate in the same way to set the minute on the timer After TIMER ON is completed continue to press to activate timer OFF setting 00 00 and will be flashing with OFF icon ...

Страница 16: ...erant 2 Check and adjust EE valve make sure EE valve sensor is well connected with return gas pipe 3 Check if EE valve broken and replacement needed Temp sensor broken or not enough refrigerant Temp sensor short circuit or open circuit Check if temp sensor in good conditions or replace related sensor 1 Check repair or replace filter 2 Check if EE valve broken and replacement needed 3 Refill certai...

Страница 17: ...ll connected with return gas pipe 3 Check if EE valve broken and replacement needed Temp sensor short circuit or open circuit Check if temp sensor in good conditions or replace related sensor 1 Check repair or replace filter 2 Check if EE valve broken and replacement needed 3 Refill certain refrigerant No action required Replace temp sensor or fill in certain refrigerant Phase protection Reserved ...

Страница 18: ... FN CM N L 12V AC 220V AC LP HP P N1 B01 4 Way Valve High pressure switch Low pressure switch BLU RED wire contr oller RY7 BLU BLU PUMP COMP RY6 4 Wayval ve Electr onic exp anding val ve Transfor mer P P 07 08 10 11 Low pressure switch switch High pressure 03 32 30 42 05 Tank sen sor connector Coil temp Ambient temp Back gas temp Exh aus t temp P 6 N1 N2 FN CM N L 12V AC 220V AC AC N Electronic RE...

Страница 19: ...a n Mi dd le Fa n El ec tr on ic ex pa nd in g va lv e Tr an sf or me r 22 0V AC 12 V AC 12 11 10 09 08 07 06 05 04 03 02 01 13 HP LP H i g h p r e s s u r e s w i t c h L o w p r e s s u r e s w i t c h 07 08 10 11 Co il te mp Am bi en t te mp Re tu rn ga s te mp Ex ha us t te mp Ta nk se ns or co nn ec to r 23 22 21 20 18 19 17 14 16 15 03 32 30 42 05 PO WE R SU PP LY Wi re co nt ro ll er N4 D0 ...

Страница 20: ...e surrounding of the unit should be kept clean with good ventilation Clean regularly 1 2 months the air side heat exchanger to maintain a good heat exchange effect 7 Check frequently the operation state of each part of the unit Check whether there is oil dirt in unit pipeline connection and air inhale valve to ensure there is no leakage of the unit refrigerant 8 Do not pile any other object around...

Отзывы: