![ITS Telecom 1700264 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/its-telecom/1700264/1700264_operation-manual_2096138028.webp)
MITS Janus Time Engine
Page 28 of 39
Copyright© Instrumentation Technology Systems 2020
20200929
Group
Command
String
Variable values
Notes
address assigned to the unit.
Netwrk DCHP or Status
IP mode
^YDHn
n=’0’; disable DHCP
n=’1’; enable DHCP (factory default)
ITS offers an ITS Client
Discovery software that
can detect and report the
current IP address of any
of its products on your
network.
^YDH?
Queries DHCP state
return =
(19h)DH(32h)DHCP(32h)ON<CR>
(enabled) or
(19h)DH(32h)DHCP(32h)OFF<CR>
(disabled)
Netwrk Static IP
Address
^YNS
###.###.###.###,
ggg.ggg.ggg.ggg,ss
s.sss.sss.sss,ppppp<
CR>
###.###.###.### =IP address,
ggg.ggg.ggg.ggg =the gateway,
sss.sss.sss =subnet mask values. ‘ppppp
=port address (23 is telnet),
Factory default=192.168.150.90,
192.168.150.100,255.255.255.000-0023
Any valid IP address.
^YNS?
Queries the current network values
Returns network information as ASCII
string.
Value formatted as:
(19h)NS(32h)DHCP mode, IP
address,Gateway address,Network
mask,Port number<CR>
Example
(19h)NS(32h)OFF,192.168.150.90,
192.168.150.100,255.255.255.0,23
<CR>
Leading zeros are
removed.
NTP
NTP Server
Address
^YNT###.###.###.
###[-ppp]<CR>
###.###.###.### =NTP server address
[] indicates optional characters do not
include in the input string.
- = declares addition of the offset option
ppp = a value (offset) -99 to +99
Factory default = 000.000.000.000
Default is
000.000.000.000 and has
no functional value unless
the JTE is in NTP slave
mode.
YNT?
Queries current NTP address
Return=(19h)NT(32h)###.###.###.###: