ITS Telecom 082255 Скачать руководство пользователя страница 6

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C 

08172 Sant Cugat del Vallés · Barcelona (Spain)  

Phone: +34935839543  ·  [email protected]  ·   www.ek.plus

 

6

 

 

CM 8SH-TC 

USER MANUAL

 

 

5c.- PC - 

CM PR

 programming via USB. Connect the module to the device using the power and data 

cable. Connect the PC to the CM PR via USB cable. 

6.- Run the PC SW programming. 

 

Important note: Connect the 

FA 524

 power supply or the 

CM PR

 programming device 

and 

FA 55

 power supply to the PC before running the software so that it is correctly 

detected by the PC driver. 

Installation of a multi-module head-end: 

In the event of wishing to install the module as a further element of a head-end consisting of other CM 
series modules it is very important to follow the instructions below. 

 Connect the different modules in series using the supplied power cable and then the power supply, 

which must always be to the left of the head-end. 

Check the consumption of the modules. In general, up to 5 modules can be connected using an FA 524 

power supply. However, it is recommended to check the power consumptions of the modules to be 
installed. 

 It is recommended to install the modules with CIs downstream of the power supply. 

 It is possible to use the long jumper to deliver the input signal to adjacent modules. 

 The attenuation at the output of each module can be adjusted to compensate for cable losses at high 

frequency. 

“CM Management” PROGRAMMING SOFTWARE

The “CM Management” programming software enables programming and 

controlling all CM head-end 

modules. The program is only available for Windows operating systems (version XP, 7 and higher). Once 
downloaded from the website 

https://ek.plus

Software / CM Head-end section, run the program after 

connecting the PC to the USB port of the FA 524 or CM PR power supply unit. This will ensure that the 
driver detects the control panel. 

Main screen: 

The main screen of the “CM Management” software is 

displayed as follows: 

 

Always check that the latest 

WEB

 software version is installed.  

It can be directly connected via USB or LAN. 
 

 

Содержание 082255

Страница 1: ...Partner O B S S L Av Cerdanyola 79 81 Local C 08172 Sant Cugat del Vall s Barcelona Spain Phone 34935839543 info ek plus www ek plus USER MANUAL CM 8SH TC 082255 DVB S S2 TO COFDM QAM TRANSMODULATOR...

Страница 2: ...ption 3 Key features 3 Package contents 3 CONNECTIONS AND INTERFACES 4 INSTALLATION AND WIRING 5 General installation and wiring 5 Installation of a multi module head end 6 CM Management PROGRAMMING S...

Страница 3: ...s OCTO module with 4 SAT inputs and 8 tuners 1 HDMI input 1 USB 2 0 input Independent control of each 13 18V 22KHz DiSEqC A B C D input Flexible remultiplexing of services on any output channel NIT ta...

Страница 4: ...5 Status LED Reports the status of the COFDM QAM modulated output The output will be working properly when the LED blinks green 6 RF mix input connector 7 RF output connector This output will supply t...

Страница 5: ...the previous module using the supplied power cable The FA 55 power supply can also be used to power a single module 3 Connect the input signals to the transmodulator inputs Important note Pay particul...

Страница 6: ...on of the modules In general up to 5 modules can be connected using an FA 524 power supply However it is recommended to check the power consumptions of the modules to be installed It is recommended to...

Страница 7: ...ny SW is available the corresponding card will be displayed with a white triangle in the inner left corner By double clicking the button will change the color to orange and the icon will change from g...

Страница 8: ...ut card green two CIs orange and one output card blue Identification of a module with two input cards green and one output card blue In this case it would be a power supply and three modules each one...

Страница 9: ...le 11229 MHz 9750 1479MHz S R Symbol Rate of the selected MUX Once the parameters have been correctly configured the signal will be acquired acquired and an approximate value of these parameters will...

Страница 10: ...MUX output DVB T output card This part of the menu consists of three differentiated sections N I T Network Information Table parameters RF output channel parameters Information window on the throughpu...

Страница 11: ...odule is changed the power supply must be reset Advanced Configuration LCN Function The transmodulator enables labeling the information Transport Streams so that the TV programs are displayed in order...

Страница 12: ...y and in each of the head end modules To do so a CM KEY 082015 code must be available Each CM KEY is associated with a single power supply and will only enable remote management of that power supply T...

Страница 13: ...e not detect anything Set the FA 524 to the left Connect the head end module to the right Plug the power to the FA 524 connect a USB cable to the PC and open the CM MANAGEMENT program Press the USB bu...

Страница 14: ...Input 1 ON Tuner A 22KHz Enabled ASTRA 19 2 E Satellite Frequency 12545 HORIZONTAL 22000 12545 10600 1945Mhz No DISEQ Input 1 Standard DVB S 9 channels in the COFDM modulated program pool 1 Channel 2...

Страница 15: ...ple 2 Input 2 ON Tuner B 22KHz Disabled ASTRA 19 2 E Satellite Frequency 10891 HORIZONTAL 22000 10891 9750 1141Mhz No DISEQ Input 1 Standard DVB S2 6 channels in the COFDM modulated program pool 2 Cha...

Отзывы: